kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Functionalized graphene oxide tablets for sample preparation of drugs in biological fluids: Extraction of ritonavir, a HIV protease inhibitor, from human saliva and plasma using LC–MS/MS
Karolinska institutet.
KTH, School of Engineering Sciences (SCI), Applied Physics, Materials and Nanophysics.ORCID iD: 0000-0001-9424-6965
Show others and affiliations
2021 (English)In: BMC Biomedical chromotography, ISSN 0269-3879, E-ISSN 1099-0801, Vol. 35, no 12, article id e5111Article in journal (Refereed) Published
Abstract [en]

In this work, graphene oxide–based tablets (GO-Tabs) were prepared by applying a thin layer of functionalized GO on a polyethylene substrate. The GO was functionalized with amine groups (–NH2) by poly(ethylene glycol)bis(3-aminopropyl) terminated (GO-NH2-PEG-NH2). The functionalized GO-Tabs were used for the extraction of ritonavir (RTV) in human saliva samples. RTV in plasma and saliva samples was analyzed using LC–MS/MS. Gradient LC system with MS/MS in the positive-ion mode [electrospray ionization (ESI+)] was used. The transitions m/z 721 → 269.0 and m/z 614 → 421 were used for RTV and the internal standard indinavir, respectively. This study determined the human immunodeficiency virus protease inhibitor RTV in human saliva samples using functionalized GO-Tab and LC–MS/MS, and the method was validated. The standard calibration curve for plasma and saliva samples was constructed from 5.0 to 2000 nmol L−1. The limit of detection was 0.1 nmol L−1, and the limit of quantification was 5.0 nmol L−1 in both plasma and saliva matrices. The intra- and inter-assay precision values were found to be between 1.5 and 5.8%, and the accuracy values ranged from 88.0 to 108% utilizing saliva and plasma samples. The extraction recovery was more than 80%, and the presented functionalized GO-Tabs could be reused for more than 10 extractions without deterioration in recovery.

Place, publisher, year, edition, pages
Wiley , 2021. Vol. 35, no 12, article id e5111
Keywords [en]
graphene oxide tablets, LC–MS/MS, plasma, ritonavir, saliva, amine, graphene oxide, macrogol derivative, nanocomposite, poly(ethylene glycol)bis (3 aminopropyl), polyethylene, unclassified drug, graphite, Human immunodeficiency virus proteinase inhibitor, nanomaterial, blood sampling, Conference Paper, drug determination, drug synthesis, human, hydrogen bond, limit of detection, limit of quantitation, liquid chromatography-mass spectrometry, positive ion electrospray, saliva analysis, tablet, chemistry, liquid chromatography, procedures, reproducibility, statistical model, tablet manufacture, tandem mass spectrometry, Chromatography, Liquid, HIV Protease Inhibitors, Humans, Linear Models, Nanostructures, Reproducibility of Results, Tablets
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-309668DOI: 10.1002/bmc.5111ISI: 000656746500001PubMedID: 33675066Scopus ID: 2-s2.0-85107333551OAI: oai:DiVA.org:kth-309668DiVA, id: diva2:1644567
Note

QC 20220314

Available from: 2022-03-14 Created: 2022-03-14 Last updated: 2024-03-18Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Laxman, KarthikUheida, AbdusalamDutta, JoydeepAbdel-Rehim, Mohamed

Search in DiVA

By author/editor
Laxman, KarthikUheida, AbdusalamDutta, JoydeepAbdel-Rehim, Mohamed
By organisation
Materials and Nanophysics
In the same journal
BMC Biomedical chromotography
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 53 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf