Evaluation of a New Simplified Inertial Sensor Method against Electrogoniometer for Measuring Wrist Motion in Occupational Studies
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems, Ergonomics.
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems, Ergonomics. ;Karolinska Inst, Inst Environm Med, Unit Occupat Med, SE-17177 Stockholm, Sweden..ORCID iD: 0000-0001-7285-824x
2022 (English)In: Sensors, E-ISSN 1424-8220, Vol. 22, no 4, p. 1690-, article id 1690Article in journal (Refereed) Published
Abstract [en]

Wrist velocity is an important risk factor for work-related musculoskeletal disorders in the elbow/hand, which is also difficult to assess by observation or self-reports. This study aimed to evaluate a new convenient and low-cost inertial measurement unit (IMU)-based method using gyroscope signals against an electrogoniometer for measuring wrist flexion velocity. Twelve participants performed standard wrist movements and simulated work tasks while equipped with both systems. Two computational algorithms for the IMU-based system, i.e., IMUnorm and IMUflex, were used. For wrist flexion/extension, the mean absolute errors (MAEs) of median wrist flexion velocity compared to the goniometer were <10.1 degrees/s for IMUnorm and <4.1 degrees/s for IMUflex. During wrist deviation and pronation/supination, all methods showed errors, where the IMUnorm method had the largest overestimations. For simulated work tasks, the IMUflex method had small bias and better accuracy than the IMUnorm method compared to the goniometer, with the MAEs of median wrist flexion velocity <5.8 degrees/s. The results suggest that the IMU-based method can be considered as a convenient method to assess wrist motion for occupational studies or ergonomic evaluations for the design of workstations and tools by both researchers and practitioners, and the IMUflex method is preferred. Future studies need to examine algorithms to further improve the accuracy of the IMU-based method in tasks of larger variations, as well as easy calibration procedures.

Place, publisher, year, edition, pages
MDPI AG , 2022. Vol. 22, no 4, p. 1690-, article id 1690
Keywords [en]
inertial measurement units, gyroscope, goniometer, wrist flexion velocity, work-related musculoskeletal disorders, ergonomics, hand-intensive work
National Category
Production Engineering, Human Work Science and Ergonomics
Identifiers
URN: urn:nbn:se:kth:diva-310238DOI: 10.3390/s22041690ISI: 000767970700001PubMedID: 35214592Scopus ID: 2-s2.0-85124904854OAI: oai:DiVA.org:kth-310238DiVA, id: diva2:1647251
Note

QC 20220325

Available from: 2022-03-25 Created: 2022-03-25 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Manivasagam, KarnicaYang, Liyun

Search in DiVA

By author/editor
Manivasagam, KarnicaYang, Liyun
By organisation
Ergonomics
In the same journal
Sensors
Production Engineering, Human Work Science and Ergonomics

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 69 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf