kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Separation and identification of IgG glycopeptides using Capillary Electrophoresis and Ultra High-Performance Liquid Chromatography-Mass Spectrometry
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Chemistry.
2022 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Separation och identifiering av IgG glykopeptider med kapillärelektrofores och ultra-högupplösande vätskekromatografi- masspektrometri (Swedish)
Abstract [sv]

I den här studien har metoder för att separera immunoglobulin (IgG) utvecklats med hjälp av kapillärelektrofores (CE) och Ultra högupplösande vätskekromatografi-Mass spektrometri (UHPLC-MS). Vid analysen av peptider från IgG spjälkat av trypsin (IgG TD) detekterades 26 glykopepeptider med UHPLC-MS genom att använda olika gradienter och mobilfaser. Dessutom analyserades fyra olika koncentrations av IgG TD för att testa detektionsgränsen. Resultatet visade att glykopeptider kunde detekteras i alla fyra koncentrationer men antalet detekterade glykopeptider minskade med minskande koncentration. Den sista delen av UHPLC-MS analysen var en selektivitetsanalys där en blandning av bovint serumalbumin spjälkat av trypsin (BSA TD) och IgG TD analyserades i olika koncentrationer. Selektivitetsanalysen visade att ungefär samma antal IgG glykopeptider detekterades som vid analys av IgG TD. Vid CE-analysen användes tre olika kapillärer, varav två av dem var polyvinylalkohol-coated och olika buffertlösningar (BGE) användes. De slutgiltiga resultaten visade 5 toppar som skulle kunna representera IgG gykopeptider men eftersom ingen MS utfördes kunde inga slutsatser dras. Slutligen, användes Matrix-Assisted Laser desorption/ionisation-time-of-flight (MALDI-TOF) för att analysera proverna innan analys och för att jämföra resultaten med UHPLC-MS.

Abstract [en]

In this study, methods to separate immunoglobulin G (IgG) glycopeptides were developed using capillary electrophoresis (CE) and ultra-high-performance liquid chromatography-Mass spectrometry (UHPLC-MS). In the UHPLC-MS- analysis, 26 glycopeptides were detected during the analysis of trypsin digested IgG (IgG TD) using different gradients and mobile phases. Moreover, a limit of detection study with four different concentrations (0.01, 0.1, 0.5 and 2mg/mL) was performed. Although the number of detected glycopeptides decreased with decreasing concentration, glycopeptides were detected in the 0.01 mg/mL IgG TD sample. Lastly, a selectivity study was performed, in which two trypsin digested Bovine serum albumin (BSA TD) and IgG TD mixtures with different concentrations were analysed. The results showed that approximately the same number glycopeptides were detected as in the IgG sample suggesting that the BSA sample did not interfere with the detection of glycopeptides. Moreover, the CE-analysis included three different capillaries and several background electrolytes (BGEs). Two of the capillaries were polyvinyl alcohol (PVA) coated. The final electropherogram showed five peaks possibly representing IgG glycopeptides but no MS were performed on the CE part leading to no conclusions for the CE-part. Matrix-Assisted Laser Desorption/Ionisation- time-of flight (MALDI-TOF) was performed throughout the project to control the samples and for comparison to the UHPLC-MS analysis.

Place, publisher, year, edition, pages
2022.
Series
TRITA-CBH-GRU ; 2022:301
Keywords [en]
Immunoglobulin G, peptides, CE, UHPLC-MS, MALDI-TOF
Keywords [sv]
Immunglobulin G, peptider, CE, UHPLC-MS, MALDI-TOF
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-321444OAI: oai:DiVA.org:kth-321444DiVA, id: diva2:1710889
Subject / course
Chemical Science and Engineering
Educational program
Degree of Master - Molecular Science and Engineering
Supervisors
Examiners
Available from: 2022-11-15 Created: 2022-11-15

Open Access in DiVA

fulltext(4876 kB)161 downloads
File information
File name FULLTEXT01.pdfFile size 4876 kBChecksum SHA-512
f91c324b886fd97147793f0c5717bd2bcb601b1e5f7145994c4ff522a6faabdcfc62f2b772b45f00f875fd119ddde0adc3c254d94f4206aebc2ab9c728dd420b
Type fulltextMimetype application/pdf

By organisation
Chemistry
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 161 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 235 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf