Parallel Operation of Grid-Forming Power Inverters
2023 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE credits
Student thesis
Abstract [en]
The use of renewable energy sources has been increasing during the last few years, both to obtain a less impacting energy production, and because of the limited fossil resources. Renewable sources are connected to the grid using inverters, which can be controlled in two main modes, grid-following, and grid-forming. Grid-following inverters (GFLIs) operate connected and synchronized to the grid. GFLIs can be considered as current sources, which adjust their output current by varying output voltage to obtain a certain power. Because GFLIs cannot form the grid voltage, they cannot operate in standalone mode. On the other hand, grid-forming inverters (GFMIs) are controlled to form their output voltage by setting the voltage amplitude and frequency. Therefore, GFMIs can be grid-connected or operate in standalone mode. The GFMIs can participate in frequency control. Thanks to this, the integration of renewable sources as GFMIs may increase electrical system reliability. In addition, GFMIs can be disconnected from the grid to work as an isolated microgrid in case of contingencies. This thesis aims to investigate and validate control methods, without communication, for the operation of parallel GFMIs in standalone mode. The thesis is divided into two main parts. The first part is related to single inverters working as GFLI and GFMI. The two operational modes are analyzed and validated in the laboratory. In particular, the disturbance rejection capabilities of the voltage control are observed by using a GFLI as controllable load. Completing the first part, a functioning system is obtained for a single inverter. The second part is dedicated to the study and validation of parallel GFMIs. In this part, two main scenarios are addressed, the case of parallel operation with inductive lines and resistive lines. For each scenario, different types of droop control are discussed. These two cases differ for the relations between the power flows and frequency and voltage variation. For the case of a mostly inductive line, active and reactive power flows are decoupled. Therefore, the proportional droop control is first considered, both for parallel inverters with equal and different droop coefficients. For the case with different coefficients, power oscillations are expected from the theory. For this reason, an improved method, which introduces a derivative term to dampen the system response, is investigated. Another control strategy for renewable energy integration is the virtual synchronous generator approach (VSG), which tries to mimic the behavior of a synchronous generator. This is analyzed, considering the first-order control and the effect of the virtual inertia on frequency variations. The system is then tested in the laboratory and the experimental results are compared for the different methods. The quality of the control is mainly assessed considering the active power-sharing between the inverters and the frequency response for a load step. In addition, the experimental results are confronted with the theory during the validation of the method. Finally, the second scenario is considered where the case of a mostly resistive line is investigated. In particular, two decoupling methods are presented and implemented for the proportional droop control with equal coefficients. The virtual impedance method is addressed, particularly regarding the impact of the virtual impedance on system dynamics. The second method is based on a linear transformation of active and reactive power flows. For this, the line parameters should be known. Therefore, the effect of accuracy on the parameters is considered. The system is then tested with a focus on the coupling behavior and the active power-sharing, and the experimental results are compared for the two decoupling methods.
Abstract [sv]
Användningen av förnybara energikällor har ökat under de senaste åren, både för att få en mindre inverkan på energiproduktionen och på grund av de begränsade fossila resurserna. Förnybara källor är anslutna till elnätet med hjälp av omvandlare, som kan styras i två läge, grid-forming inverters (GFMIs) och grid-following inverters. GFLI-omvandlare (Grid-following inverters) fungerar ansluten och synkroniserad med elnätet. GFLIs kan betraktas som strömkällor, som justerar deras utgångsström genom att variera utspänning för att erhålla en viss eleffekt. GFLIs kan inte fungera i isolerat funktionsläge, därför att de kan inte blankett spänningen. GFMIs kan bilda utspänningen i amplitud och frekvens. Därför kan de arbeta i isolerat läge eller elnätsanlugtning läge. GFMIs kan delta i frekvenskontroll. Detta kan bidra till integreringen av förnybara källor. Denna avhandling syftar till att undersöka och validera kontrollmetoder, utan kommunikation, för drift av parallella GFMIs i isolerat läge. Avhandlingen är uppdelad i två huvuddelar. Den första delen är relaterad till single GFLI och GFMI. De två driftlägena analyseras och valideras i laboratoriet. Den andra delen ägnas åt studier och validering av parallella GFMIs. Två huvudsakliga scenarier tas upp, fallet med parallell drift med induktiva linjer och resistiva linjer. För varje scenario diskuteras olika typer av droop kontroll. Dessa två fall skiljer sig åt för relationerna mellan kraftflöden och frekvens- och spänningsvariation. För induktiva ledningar är aktiva och reaktiva effektflöden frånkopplade. Därför är den proportionella droop kontroll först beaktas, både för parallella inverterare med lika och olika droop koefficienter. Dessutom studeras och testas en förbättrad metod baserad på en derivatterm. Den tredje metoden är den virtuella synkrona generatorn (VSG), som emulerar dynamiken i en synkron generator. För resistiva ledningar presenteras två frånkopplingsmetoder. Den första är den virtuella impedansmetoden, som emulerar närvaron av en induktor. Den andra metoden är baserad på linjär transformation av aktiv och reaktiv effekt. Alla studerade metoder för induktiva och resistiva linjer simuleras och testas i laboratoriet.
Place, publisher, year, edition, pages
2023. , p. 89
Series
TRITA-EECS-EX ; 2023:107
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-325856OAI: oai:DiVA.org:kth-325856DiVA, id: diva2:1751355
External cooperation
Imperix; Politecnico di Torino
Supervisors
Examiners
2023-06-272023-04-172023-06-27Bibliographically approved