Flödesavvikelser hos infusionspumpar: Slangsetets roll
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems.
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Biomedical Engineering and Health Systems.
2023 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Flow Deviations in Infusion Pumps : The Role of the Administration Set (English)
Abstract [sv]

På Karolinska Universitetssjukhuset har det återkommande rapporterats om flödesavvikelser hos infusionspumpar. En hypotes är att pumpanvändare drar i infusionsaggregates silikondel när en infusion förbereds och att detta ger upphov till flödesavvikelser. Detta projekt fokuserar på att utreda om töjning av slangsetets silikondel kan orsaka flödesavvikelser. Projektet utvärderade tre grupper av slangset där två av grupperna bestod av infusionsaggregat vars silikondel töjdes till olika längder och en grupp fungerade som referensgrupp. Resultatet visar att silikondelen förlängs vid töjning samt att flödesavvikelser uppstår om töjningen är tillräckligt stor. Trots att flödesavvikelserna påvisats så bedöms töjningen som utförts vara mycket större än den töjning som utförts av vårdpersonalen. Därför bedömmer vi att flödesavvikelserna som rapporterats på Karolinska Universitetssjukhuset inte beror på denna typ av felhantering av slangset.

Abstract [en]

At Karolinska University Hospital, recurrent reports of flow deviations in infusion pumps have been observed. One hypothesis is that pump users pull the silicone component of the administration set when preparing an infusion, leading to flow deviations. This project focuses on investigating whether elongation of the silicone component of the administration set can cause flow deviations. The project evaluated three groups of administration sets, where two groups consisted of administration sets which were elongated to different lenghts, while one group served as reference group. Results show that elongation of the silicone component occurs and that flow deviations occur if the elongation is large enough. However, despite the observed flow deviations, the elongation performed in the study is considered much larger than what healthcare personnel typically apply. Therefore, we find it unlikely that the reported flow deviations at Karolinska University Hospital are due to mishandling of the administration set.

Place, publisher, year, edition, pages
2023. , p. 56
Series
TRITA-CBH-GRU ; 2023:117
Keywords [en]
Infusionpump, Administrations set, Flow Deviation
Keywords [sv]
Infusionspump, Infusionsaggregat, Flödesavvikelse
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:kth:diva-330302OAI: oai:DiVA.org:kth-330302DiVA, id: diva2:1777766
External cooperation
Karolinska Universitetssjukhuset
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
Supervisors
Examiners
Available from: 2023-07-04 Created: 2023-06-30 Last updated: 2023-07-04Bibliographically approved

Open Access in DiVA

Flödesavvikelser hos infusionspumpar(10905 kB)357 downloads
File information
File name FULLTEXT01.pdfFile size 10905 kBChecksum SHA-512
a7879c17c6d7566d239a6e4b00aaf1a84bf96715419f7716d79981083ea686bdc8df8d3cbcbd7ccb82d39c85113529d56b7a555e9909b08de007410d2824074f
Type fulltextMimetype application/pdf

By organisation
Biomedical Engineering and Health Systems
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 358 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 275 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf