A novel noble metal stent coating reduces in vitro platelet activation and acute in vivo thrombosis formation: a blinded study
KTH, School of Electrical Engineering and Computer Science (EECS), Intelligent systems, Micro and Nanosystems. Department of Clinical Neuroscience, Karolinska Institute, Tomtebodavägen 18A, 171 77, Stockholm, Sweden, Tomtebodavägen 18A; MedTechLabs, Stockholm, Sweden.ORCID iD: 0000-0003-1235-9099
Bactiguard AB, Alfred Nobels allé 150, 146 48, Tullinge, Sweden, Alfred Nobels allé 150.
Department of Clinical Neuroscience, Karolinska Institute, Tomtebodavägen 18A, 171 77, Stockholm, Sweden, Tomtebodavägen 18A.
Bactiguard AB, Alfred Nobels allé 150, 146 48, Tullinge, Sweden, Alfred Nobels allé 150.
Show others and affiliations
2023 (English)In: Scientific Reports, E-ISSN 2045-2322, Vol. 13, no 1, article id 17225Article in journal (Refereed) Published
Abstract [en]

Inherent to any stenting procedure is the prescription of dual antiplatelet therapy (DAPT) to reduce the platelet response. Clinical guidelines recommend 6–12 months of DAPT, depending on stent type, clinical picture and patient factors. Our hypothesis is that a nanostructured noble metal coating has the potential to reduce protein deposition and platelet activation. These effects would reduce subsequent thrombo-inflammatory reactions, potentially mitigating the need for an extensive DAPT in the acute phase. Here, a noble metal nanostructure coating on stents is investigated. Twelve pigs underwent endovascular implantation of coated and non-coated stents for paired comparisons in a blinded study design. The non-coated control stent was placed at the contralateral corresponding artery. Volumetric analysis of angiographic data, performed by a treatment blinded assessor, demonstrated a significant thrombus reduction for one of the coatings compared to control. This effect was already seen one hour after implantation. This finding was supported by in vitro data showing a significant reduction of coagulation activation in the coated group. This novel coating shows promise as an implant material addition and could potentially decrease the need for DAPT in the early phases of stent implementation.

Place, publisher, year, edition, pages
Springer Nature , 2023. Vol. 13, no 1, article id 17225
National Category
Cardiology and Cardiovascular Disease
Identifiers
URN: urn:nbn:se:kth:diva-338883DOI: 10.1038/s41598-023-44364-4ISI: 001116585900067PubMedID: 37821529Scopus ID: 2-s2.0-85173667879OAI: oai:DiVA.org:kth-338883DiVA, id: diva2:1808390
Note

Not duplicate with DiVA 1786310

QC 20231031

Available from: 2023-10-31 Created: 2023-10-31 Last updated: 2025-02-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Sandell, Mikael

Search in DiVA

By author/editor
Sandell, Mikael
By organisation
Micro and Nanosystems
In the same journal
Scientific Reports
Cardiology and Cardiovascular Disease

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 54 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf