kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energibesparing med FX och FTX
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2023 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Energy saving with different HRV systems (English)
Abstract [sv]

Idag har de flesta hus från miljonprogrammet i Svenska Bostäders fastighetsbestånd ettfrånluftssystem utan någon värmeåtervinning. Det finns stora möjligheter att ta vara på värmen i denfrånluft som lämnar byggnaden.Det finns idag primärt två olika sätt att återvinna värmen ur frånluften i flerbostadshus.FX återvinner värme ur frånluften och använder den sedan till uppvärmning av fastigheten och dessvarmvatten.FTX återvinner värme genom att värmeväxla inkommande uteluft med utgående frånluft för attförvärma tilluften direkt in till lägenheterna.Denna rapport syftar till att jämföra dessa två ventilationssystem och se vilken av dessa som har bästenergibesparing, lönsamhet och innemiljö.Jämförelsen bygger på en statistisk modell som kopplar samman byggnaders ventilationssystem meddess energianvändning och upplevda innemiljö för att avgöra vilket system som är bäst ur energi- ochhälsosynpunkt. Energibesparingen ställs sedan mot kostnader för investering och underhåll i enlönsamhetsbedömning.Resultatet av denna rapport visar på att FX har en avsevärt kortare återbetalningstid än FTX. Dettaberor till största del på att investeringskostnaden är betydligt lägre för en FX-renovering. Resultatetvisar också på att det inte finns någon tydlig korrelation mellan ventilationssystem och upplevdförbättring av innemiljön.

Abstract [en]

Today, most houses from “Miljonprogrammet” in Svenska Bostäder´s property portfolio have anexhaust air system without any heat recovery. There are significant opportunities to recover the heatfrom the exhaust air leaving the building.Currently, there are primarily two different ways to recover heat from the exhaust air in multi-familyhouses.FX recovers heat from the exhaust air and uses it for heating the property and its hot water supply.FTX recovers heat by heat exchanging incoming outdoor air with outgoing exhaust air to preheat thesupply air directly into the apartments.This report aims to compare these two ventilation systems and determine which one provides thebest energy savings, profitability, and indoor environment. The comparison is based on a statisticalmodel that links a building's ventilation system to its energy consumption and perceived indoorenvironment to determine which system is best in terms of energy and health. The energy savingsare then assessed against investment and maintenance costs for profitability evaluation.The results of this report show that FX has a significantly shorter payback period than FTX. This ismainly since the investment cost is considerably lower for an FX renovation. The results also indicatethat there is no significant correlation between these ventilation systems and the perceivedimprovement in the indoor environment.

Place, publisher, year, edition, pages
2023.
Series
TRITA-ABE-MBT ; 23575
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-339063OAI: oai:DiVA.org:kth-339063DiVA, id: diva2:1809388
Supervisors
Examiners
Available from: 2023-11-03 Created: 2023-11-03

Open Access in DiVA

fulltext(1537 kB)915 downloads
File information
File name FULLTEXT01.pdfFile size 1537 kBChecksum SHA-512
baca1fe0740e5ffda72ad2c07a85d8ca7179be72a8434d403faeada429de23b70b3708efabaa1cb363f95376924eb09e4ba6077364834f81be574ebe770c7d92
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 915 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 486 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf