kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Biomechanical Variability and Usability of a Novel Customizable Fracture Fixation Technique
Department of Orthopedic Surgery, Hvidovre University Hospital, Kettegaard Allé 30, Hvidovre, 2650, Denmark.
AO Research Institute Davos, Clavadelerstrasse 8, Davos, 7270, Switzerland.
Department of Orthopedic Surgery, Gentofte Hospital, Gentofte Hospitalsvej 1, Hellerup, 2900, Denmark.
Department of Orthopedic Surgery, Copenhagen University Hospital, Blegdamsvej 9, Copenhagen, Rigshospitalet, 2100, Denmark.
Show others and affiliations
2023 (English)In: Bioengineering, E-ISSN 2306-5354, Vol. 10, no 10, article id 1146Article in journal (Refereed) Published
Abstract [en]

A novel in situ customizable osteosynthesis technique, Bonevolent™ AdhFix, demonstrates promising biomechanical properties under the expertise of a single trained operator. This study assesses inter- and intra-surgeon biomechanical variability and usability of the AdhFix osteosynthesis platform. Six surgeons conducted ten osteosyntheses on a synthetic bone fracture model after reviewing an instruction manual and completing one supervised osteosynthesis. Samples underwent 4-point bending tests at a quasi-static loading rate, and the maximum bending moment (BM), bending stiffness (BS), and AdhFix cross-sectional area (CSA: mm²) were evaluated. All constructs exhibited a consistent appearance and were suitable for biomechanical testing. The mean BM was 2.64 ± 0.57 Nm, and the mean BS was 4.35 ± 0.44 Nm/mm. Statistically significant differences were observed among the six surgeons in BM (p < 0.001) and BS (p = 0.004). Throughout ten trials, only one surgeon demonstrated a significant improvement in BM (p < 0.025), and another showed a significant improvement in BS (p < 0.01). A larger CSA corresponded to a statistically significantly higher value for BM (p < 0.001) but not for BS (p = 0.594). In conclusion, this study found consistent biomechanical stability both across and within the surgeons included, suggesting that the AdhFix osteosynthesis platform can be learned and applied with minimal training and, therefore, might be a clinically viable fracture fixation technique. The variability in BM and BS observed is not expected to have a clinical impact, but future clinical studies are warranted.

Place, publisher, year, edition, pages
MDPI AG , 2023. Vol. 10, no 10, article id 1146
Keywords [en]
in situ customizable osteosynthesis, patient-specific osteosynthesis, surgical skills, usability, variability
National Category
Orthopaedics Dentistry
Identifiers
URN: urn:nbn:se:kth:diva-339521DOI: 10.3390/bioengineering10101146ISI: 001098167200001Scopus ID: 2-s2.0-85175168908OAI: oai:DiVA.org:kth-339521DiVA, id: diva2:1811569
Note

QC 20231204

Available from: 2023-11-13 Created: 2023-11-13 Last updated: 2024-02-29Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

San Jacinto García, JorgeHutchinson, Daniel JohnMalkoch, Michael

Search in DiVA

By author/editor
San Jacinto García, JorgeHutchinson, Daniel JohnMalkoch, Michael
By organisation
Coating Technology
In the same journal
Bioengineering
OrthopaedicsDentistry

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 157 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf