Digitalisera tryckmätning över filter hos AstraZeneca
KTH, School of Industrial Engineering and Management (ITM), Production engineering.
KTH, School of Industrial Engineering and Management (ITM), Production engineering.
2023 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Digitalization of pressure measurement over filters at AstraZeneca (English)
Abstract [sv]

AstraZeneca är ett medicinskt företag lokaliserat i Södertälje som har cirka 900 luftfilterboxar hos sin anläggning i Gärtuna. Dessa filterboxar kan vara opraktiska att hålla koll på eftersom de är utspridda uppe på vindarna, samt att det behövs bra framförhållning vid filterbyten eftersom vissa filter innehåller farliga ämnen. Filterboxar är utrustade med analoga tryckmätare vilket innebär att det kan bli omständigt för personalen att övervaka filtrets tryckfall.

Målet med det här examensarbetet är att hitta en digital lösning som underlättar övervakningen av tryckfall över filter i realtid, samt informerar via sms eller mejl när det är dags att planera in filterbyte. Visionen är att det ska bli enklare att få en bild över luftfiltrets underhållsmässiga skick.

Genom att jämföra olika produkter och delta i regelbundna möten med IT kunnig personal valdes en lämplig produkt. Projektet har arbetat metodiskt och strukturerat genom att följa projektmodellen projekt case där verktygen GANTT-schema, SWOT-analys, FMEA och maxiriskmetoden har använts.

Projektet resulterade i användningen av digitala differentialtryckgivare som mäter tryckfallet över filter. Differentialtryckgivaren samlar data som sedan skickas via radiofrekvens till en Ethernet gateway som är trådad in till AstraZenecas segregerade nätverk så kallat FAB-net. Därefter förs datan från ethernet gatewayen till mjukvara. I mjukvaran kommer AstraZenecas filtergrupp kunna se över tryckfall hos de olika filtrena i filterboxarna. Detta kommer underlätta personalens arbete och eventuellt spara AstraZeneca tid och pengar.

Abstract [en]

AstraZeneca is a medical company located in Södertälje that has around 900 air filter boxes at its facility in Gärtuna. These filter boxes can be impractical to keep track of as they are scattered up in the attics and good foresight is needed for multiple filter changes as some filters contain harmful substances. Filter boxes are equipped with analog pressure gauges, which means that there is a lot of walking for the staff in order to monitor the filter's pressure drop.

The goal of this thesis is to find a digital solution that can facilitate the monitoring of pressure drops across filters in real time and that also informs by text message or email when it is time to schedule a filter change. The vision is that it will be easier to get a digital image of the maintenance condition of the air filter.

By comparing different products and participating in regular meetings with AstraZeneca's IT personnel, a suitable product was chosen. The project has worked methodically and structured by following the project model project case where tools such as GANTT chart, SWOT analysis, FMEA and maxirisk method have been used.

The project resulted in the use of digital differential pressure sensors that measure the pressure drop across filters. The differential pressure sensor collects data which is then sent by radio frequency to an ethernet gateway which is wired into AstraZeneca's segregated network called FAB-net. The data is then transferred from the ethernet gateway to the software. AstraZeneca's filter group will be able to review the pressure drop of the various filters within the software, which will facilitate their way of working and potentially save AstraZeneca time and money.

Place, publisher, year, edition, pages
2023. , p. 85
Series
TRITA-ITM-EX ; 2023:625
Keywords [en]
Differential pressure sensor, Maintenance, Predictive maintenance, Ethernet Gateway, Filter, ISO 16890, F7 Filter, Wired sensor, Wireless sensor, IIoT, Big Data, Industry 4.0
Keywords [sv]
Differentialtryckgivare, Underhåll, Prediktivt underhåll, Ethernet Gateway, Filter, ISO 16890, F7 filter, Trådbunden givare, Trådlösa givare, IIoT, Big data, Industri 4.0
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-343366OAI: oai:DiVA.org:kth-343366DiVA, id: diva2:1836935
External cooperation
AstraZeneca AB
Supervisors
Examiners
Available from: 2024-02-12 Created: 2024-02-12

Open Access in DiVA

fulltext(1502 kB)140 downloads
File information
File name FULLTEXT01.pdfFile size 1502 kBChecksum SHA-512
79662376de020d0193ae9559cf1075bce78cfc9fd6dcf63e8300a05373963724e46605e31415c36fc55583abbfed4be3dcec6bc969e9364255d58796be460f24
Type fulltextMimetype application/pdf

By organisation
Production engineering
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 140 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 204 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf