kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Undersökning av passiva strålningskylare och dess potential
KTH, School of Industrial Engineering and Management (ITM).
KTH, School of Industrial Engineering and Management (ITM).
2024 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

I och med de ständigt stigande medeltemperaturerna i världen, tillsammans med en ökande levnadsstandard i flera större utvecklingsländer, har efterfrågan på kyla ökat. En ökning som förväntas fortsätta växa in i framtiden. Behovet av nya energieffektiviserande åtgärder och tekniker inom kyltekniken har som resultat fått större uppmärksamhet de senaste decenniet. Syftet med denna studie är att undersöka en ny kylteknik vid namn Passive Radiative Cooling. Genom att testa aluminiumpaneler vars yta är behandlade med denna teknik, kan den nya teknikens potential undersökas. Är ett system bestående av dessa ytbehandlade paneler och ett cirkulerande medium förnuftigt som en energieffektiviserande åtgärd för underkylning av redan befintliga kylsystem, genererar tekniken en kyleffekt? Hur stor är i så fall kyleffekten och vilka faktorer påverkar teknikens prestanda?

De kylpaneler som studien undersökte installerades uppe på ett tak på KTH och sammankopplades med ett rörsystem där medie bestående av propylenglykol blandat med vatten flödade. Genom att variera hastigheten med vilket mediet flödade genom kylpanelerna, tillföra olika stora mängder värmeeffekt till systemet och mäta temperaturen innan och efter panelerna kunde den effekt med vilket panelerna kylt mediet beräknas. Undersökningen ägde rum från slutet av april till början av maj.

Resultatet från studien kom fram till att kylpanelernas genomsnittliga kyleffekt under hela mätperioden var 605 W, med en maximal uppmätt effekt på 1625 W och en minimal uppmätt effekt på -675 W. Att faktorer som tidpunkt på dygnet, omgivningstemperatur och väderförhållande även påverkade kylpanelernas prestanda framgick av resultatet.

Abstract [en]

With constantly rising average temperatures worldwide, coupled with an increasing standard of living in several major developing countries, the demand for cooling has increased. A development expected to continue into the future. The need for energy-efficient solutions and new technologies in the refrigeration industry has received greater attention in recent decades as a result of this development. The purpose of this study is to investigate a new cooling technology called Passive Radiative Cooling. By testing aluminum panels treated with this technology, the new technologys’ potential can be examined. Is a system consisting of these treated panels and a circulating medium sensible as an energy-efficient solution for cooling already existing refrigeration systems? Does the technology generate a cooling effect and if so, how large is the cooling effect and what factors affect the performance of the technology? The cooling panels examined in the study were installed on a roof at KTH and connected to a piping system where a medium existing of propylene glycol mixed with water flowed. By varying the speed at which the medium flowed through the cooling panels, different amounts of heat were added to the system, and by measuring the temperature before and after th epanels, the cooling effect of the panels could be calculated. The study took place from the endof April to the beginning of May.

The results of the study found that the average cooling effect of the cooling panels during the entire measurement period was 605 W, with a maximum measured effect of 1625 W and a minimum measured effect of -675 W. The results also showed that factors such as the time of day, ambient temperature, and weather conditions also affected the performance of the cooling panel 

Place, publisher, year, edition, pages
2024. , p. 46
Series
TRITA-ITM-EX ; 2024:184
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-353096OAI: oai:DiVA.org:kth-353096DiVA, id: diva2:1897121
Supervisors
Examiners
Available from: 2024-09-12 Created: 2024-09-12 Last updated: 2024-09-12Bibliographically approved

Open Access in DiVA

fulltext(7598 kB)36 downloads
File information
File name FULLTEXT01.pdfFile size 7598 kBChecksum SHA-512
91b9d50a806912b4d7b187fbcf1d4b90aa1ea34bce2a00e7ae1bae05550235d87e67c427eb4db4300bf22a4f363e5dbcd63fce204dc718f999fe947464f7d743
Type fulltextMimetype application/pdf

By organisation
School of Industrial Engineering and Management (ITM)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 36 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 89 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf