The impact of tube voltage on the erosion of rotating x‐ray anodes
KTH, School of Engineering Sciences (SCI), Physics, Particle Physics, Astrophysics and Medical Imaging. (Physics of Medical Imaging)ORCID iD: 0000-0001-6243-681X
KTH, School of Industrial Engineering and Management (ITM), Materials Science and Engineering, Process.ORCID iD: 0000-0002-6339-4612
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Space and Plasma Physics. (Division of Space and Plasma Physics)ORCID iD: 0000-0001-9632-8104
KTH, School of Engineering Sciences (SCI), Physics, Particle Physics, Astrophysics and Medical Imaging. (Physics of Medical Imaging)ORCID iD: 0000-0002-3039-9791
2025 (English)In: Medical physics (Lancaster), ISSN 0094-2405, Vol. 52, no 2, p. 814-825Article in journal (Refereed) Published
Abstract [en]

Background

The permitted input power density of rotating anode x-ray sources is limited by the performance of available target materials. The commonly used simplified formulas for the focal spot surface temperature ignore the tube voltage despite its variation in clinical practice. Improved modeling of electron transport and target erosion, as proposed in this work, improves the prediction of x-ray output degradation by target erosion, the absolute x-ray dose output and the quality of diagnostic imaging and orthovolt cancer therapy for a wide range of technique factors.

Purpose

Improved modeling of electronic power absorption to include volume effects and surface erosion, to improve the understanding of x-ray output degradation, enhance the reliability of x-ray tubes, and safely widen their fields of use.

Methods

We combine Monte Carlo electron transport simulations, coupled thermoelasticity finite element modelling, erosion-induced surface granularity, and the temperature dependence of thermophysical and thermomechanical target properties. A semi-empirical thermomechanical criterion is proposed to predict the target erosion. We simulate the absorbed electronic power of an eroded tungsten-rhenium target, mimicked by a flat target topped with a monolayer of spheres, and compare with a pristine target.

Results

The absorbed electronic power and with it the conversion efficiency varies with tube voltage and the state of erosion. With reference to 80 kV (100%), the absorption of a severely eroded relative to a pristine target is 105% (30 kV), 99% (100 kV), 97% (120 kV), 96% (150 kV), 93% (200 kV), 87% (250 kV), and 79% (300 kV). We show that, although the simplistic Müller–Oosterkamp model of surface heating underestimates the benefit of higher tube voltages relative to operation at 80 kV, the error is limited to below −6% for 30 kV (reduction advised) and +13% for 300 kV (input power increase permitted).

Conclusions

Correcting the x-ray conversion efficiency of eroded target material, that is typically not accessible by measuring the tube current, may imply corrections to existing x-ray dose calculations. The relative increase of the allowable anode input power of rotating anode x-ray tubes with increasing tube voltage is substantially smaller than predicted by volume heating models that only rely on the focal spot surface temperature. The widely used voltage agnostic Müller–Oosterkamp formalism fails to predict the tube voltage dependency of the surface temperature of rotating anode targets, ignores the temperature dependency of the thermal diffusivity of tungsten-rhenium, and the granularity of the material. Nevertheless, we show theoretically why, backed by experience, the practical use of the Müller–Oosterkamp formalism is justified in medical imaging and provides a basis for comparison with new microparticle based targets. The reason for this surprising finding is that voltage dependent material erosion must be primarily considered as a precursor of thermal runaway effects.

Place, publisher, year, edition, pages
Wiley , 2025. Vol. 52, no 2, p. 814-825
Keywords [en]
X-ray source; X-ray tube; spectral imaging; microparticle target; monochromatic X-rays; rotating anode; tungsten; medical imaging; non-destructive X-ray testing; rotating anode; tungsten; medical imaging; non-destructive X-ray testing
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
Medical Technology
Identifiers
URN: urn:nbn:se:kth:diva-359464DOI: 10.1002/mp.17528ISI: 001393245200001Scopus ID: 2-s2.0-85209748497OAI: oai:DiVA.org:kth-359464DiVA, id: diva2:1934055
Note

QC 20250203

Available from: 2025-02-03 Created: 2025-02-03 Last updated: 2025-02-03Bibliographically approved
In thesis
1. A Compact X-Ray Source via Fast Microparticle Streams: A novel X-ray target concept
Open this publication in new window or tab >>A Compact X-Ray Source via Fast Microparticle Streams: A novel X-ray target concept
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Place, publisher, year, edition, pages
Stockholm, Sweden: KTH Royal Institute of Technology, 2025. p. 52
Series
TRITA-SCI-FOU ; 2025:08
Keywords
X-ray source; X-ray tube; rotating anode; microparticle target; tungsten; medical imaging; orthovolt therapy; non-destructive X-ray testing, Röntgenkälla; röntgenrör; roterande anod; mikropartikelmål; volfram; medicinsk avbildning; ortovoltterapi; oförstörande röntgenprovning
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
Medical Technology
Identifiers
urn:nbn:se:kth:diva-359471 (URN)978-91-8106-197-0 (ISBN)
Public defence
2025-03-05, Sal FD05, Roslagstullsbacken 21 (Alba Nova), SE – 106 91 Stockholm, 09:15 (English)
Opponent
Supervisors
Available from: 2025-02-03 Created: 2025-02-03 Last updated: 2025-02-21Bibliographically approved

Open Access in DiVA

fulltext(2177 kB)62 downloads
File information
File name FULLTEXT01.pdfFile size 2177 kBChecksum SHA-512
4c8f1b9a124e43837865cc58b24a2f7181fa641b2e12e60092fd961c1ba1780002369648ca09c8f8ec92360f843a452983e40382961217b4a54ff886a2f660a4
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Behling, RolfHulme-Smith, ChristopherTolias, PanagiotisDanielsson, Mats

Search in DiVA

By author/editor
Behling, RolfHulme-Smith, ChristopherTolias, PanagiotisDanielsson, Mats
By organisation
Particle Physics, Astrophysics and Medical ImagingProcessSpace and Plasma Physics
In the same journal
Medical physics (Lancaster)
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 62 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 795 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf