Consequences of DC components in AC railways and their elimination.
Uppsala University.
Uppsala University.ORCID iD: 0000-0002-1607-2493
Rejlers Ingenjörer AB, Västerås, Sweden.
2007 (English)In: Proceedings of Railway Engineering 2007, London, UK., Jun. 2007, 2007Conference paper, Published paper (Other academic)
Place, publisher, year, edition, pages
2007.
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:kth:diva-14312OAI: oai:DiVA.org:kth-14312DiVA: diva2:332181
Conference
Railway Engineering
Note

QC 20100803

Available from: 2010-08-03 Created: 2010-08-03 Last updated: 2016-08-31Bibliographically approved
In thesis
1. Conducted and Radiated Electromagnetic Interference in Modern Electrified Railways with Emphasis on Pantograph Arcing
Open this publication in new window or tab >>Conducted and Radiated Electromagnetic Interference in Modern Electrified Railways with Emphasis on Pantograph Arcing
2009 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Arcing from the pantograph, a commonly observed phenomenon, is knownto be a major source of wideband electromagnetic emission which is more pronounced during the winter. Experience within the railway industry has shown that this source of EMI and its characteristics need to be understood thoroughly for solving the associated EMI issues in the desired fashion. This thesis investigates EMI generation from pantograph arcing. The First phase of the work is based on experimental investigations and analyses conducted on a test setup which closely resembles pantographcontact wire interaction. Different possible mechanisms of the pantograph arcing and inuencing parameters like speed of the train, loadcurrent, voltage level, power factor etc. are identified. It was found that pantograph arcing is a polarity dependent phenomenon. It generates transients and asymmetrically distorted voltage and current waveforms. This in turn generates a net DC component and odd and even harmonics(up to order 10 was measured). In the second phase, different characteristics of these high frequency emission and inuencing parameters have been analyzed and presented. Presence of wideband high frequency components in the range from afew ten kHz to a few hundred MHz at measured current, electric and magnetic elds were confirmed. 10-90 % risetimes for current was measured from 5 ns to typically around 25 ns, whereas for electric field this is ranged from fraction of onens to 25 ns. Although there are variations, the rise times of the measuredtime domain waveform of current, electric and magnetic seems to have correlation with the higher frequency components. It was understood that major high frequency components measured could be from: (a) thearcing itself, (b) radiation from connected cables/wires, (c) resonance inthe associated circuits and (d) associated digital circuitry.This wideband electromagnetic emission causes interference in traction power, signalling and train control systems. Their possible propagation paths and consequences on different equipments are also elaborated.

Place, publisher, year, edition, pages
Stockholm: KTH, 2009. xvi, 163 p.
Series
Trita-EE, ISSN 1653-5146 ; 2009:029
National Category
Control Engineering
Identifiers
urn:nbn:se:kth:diva-10574 (URN)978-91-7415-345-3 (ISBN)
Public defence
2009-06-01, sal F3, KTH, Lindstedtv 26, Stockholm, 09:30 (English)
Opponent
Supervisors
Note
QC 20100803Available from: 2009-05-27 Created: 2009-05-27 Last updated: 2012-03-26Bibliographically approved

Open Access in DiVA

No full text

Authority records BETA

Thottappillil, Rajeev

Search in DiVA

By author/editor
Midya, SurajitThottappillil, Rajeev
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 137 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf