Change search
ReferencesLink to record
Permanent link

Direct link
Effects of ultrasound contrast agents on Doppler tissue velocity estimation
KTH, School of Technology and Health (STH), Medical Engineering.
Show others and affiliations
2006 (English)In: Journal of the American Society of Echocardiography, ISSN 0894-7317, E-ISSN 1097-6795, Vol. 19, no 2, 154-164 p.Article in journal (Refereed) Published
Abstract [en]

The combination of Doppler tissue imaging and myocardial contrast echocardiography has the potential to provide information about motion and perfusion of the myocardium in a single examination. The purpose of this study was to establish how the presence of ultrasound contrast agent (UCA) affects measurements of Doppler tissue velocities in vivo and in vitro. We performed echocardiography in 12 patients with ischemic heart disease before and immediately after a slow intravenous infusion of the UCA Optison, using color Doppler tissue imaging to examine the effect of contrast agents in vivo. The myocardial peak systolic velocities and their integrals were analyzed in digitally stored cineloops before and after contrast administration. To distinguish between methodologic and physiologic factors affecting the measurement of tissue velocity in vitro, experiments with a rotating disk and a flow cone phantom were also carried out for the 3 contrast agents: Optison, Sonovue, and Sonazoid. in vivo results show that the values for peak systolic velocity increased by about 10% during contrast infusion, from mean 5.2 +/- 1.8 to 5.7 +/- 2.3 cm/s (P = .02, 95% confidence interval 2%-16%). The increase in myocardial peak systolic velocities was verified in experimental models in which the UCA increased the estimated mean velocity in the order of 5% to 20% for the motion interval of 5 to 7 cm/s, corresponding to the myocardial velocities studied in vivo. The response was similar for all 3 contrast agents and was not affected by moderate variations in concentration of the agent. We have shown that the presence UCA will affect Doppler tissue measurements in vivo and in vitro. The observed bias is presumed to be an effect of harmonic signal contribution from rupturing contrast agent microbubbles and does not indicate biologic or physiologic effects.

Place, publisher, year, edition, pages
2006. Vol. 19, no 2, 154-164 p.
Keyword [en]
acute-myocardial-infarction, blood-flow, in-vitro, mode images, microbubbles, echocardiography, destruction, growth, shift, vivo
URN: urn:nbn:se:kth:diva-15422DOI: 10.1016/j.echo.2005.09.025ISI: 000235319300007ScopusID: 2-s2.0-31944434259OAI: diva2:333463
QC 20100525Available from: 2010-08-05 Created: 2010-08-05 Last updated: 2010-10-04Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Brodin, Lars-Åke
By organisation
Medical Engineering
In the same journal
Journal of the American Society of Echocardiography

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 17 hits
ReferencesLink to record
Permanent link

Direct link