Change search
ReferencesLink to record
Permanent link

Direct link
A new computed tomography-based radiographic method to detect early loosening of total wrist implants
Karolinska Institute, Department of Molecular Medicine and Surgery.
New York University, Department of Radiology. (Nuclear Medicine)
KTH, School of Information and Communication Technology (ICT), Communication Systems, CoS. (Computer Communications)ORCID iD: 0000-0002-6066-746X
Saya Systems Inc., Salt Lake City, UT, USA.
Show others and affiliations
2007 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 48, no 9, 997-1003 p.Article in journal (Refereed) Published
Abstract [en]

Background: Diagnosis of loosening of total wrist implants is usually late using routine radiographs. Switching modality to computed tomography (CT) should aid in early diagnosis. Purpose: To propose and evaluate the accuracy of a new CT method for assessing loosening of the carpal component in total wrist arthroplasty. Material and Methods: A protocol encompassing volume registration of paired CT scans of patients with unexplained pain in a prosthetically replaced wrist (used in clinical routine) is presented. Scans are acquired as a dynamic examination under torsional load. Using volume registration, the carpal component of the prosthesis is brought into spatial alignment. After registration, prosthetic loosening is diagnosed by a shift in position of the bones relative to the prosthesis. This study is a preclinical validation of this method using a human cadaverous arm with a cemented total wrist implant and tantalum markers. Seven CT scans of the arm were acquired. The scans were combined into 21 pairs of CT volumes. The carpal component was registered in each scan pair, and the residual mismatch of the surrounding tantalum markers and bone was analyzed both visually and numerically. Results: The detection limit for prosthetic movement was less than 1 mm. Conclusion: The results of this study demonstrate that CT volume registration holds promise to improve detection of movement of the carpal component at an earlier stage than is obtainable with plain radiography.

Place, publisher, year, edition, pages
London, UK: Informa Healthcare, 2007. Vol. 48, no 9, 997-1003 p.
Keyword [en]
adults, CT, computer applications, 3D, computer applications, detection, diagnosis, wrist, hip-arthroplasty, radiostereometry, migration
National Category
Orthopedics Radiology, Nuclear Medicine and Medical Imaging
Research subject
URN: urn:nbn:se:kth:diva-17135DOI: 10.1080/02841850701499417ISI: 000251240300010OAI: diva2:335178
QC 20100525Available from: 2010-08-05 Created: 2010-08-05 Last updated: 2013-09-09Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Maguire Jr., Gerald Q.
By organisation
Communication Systems, CoS
In the same journal
Acta Radiologica
OrthopedicsRadiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 122 hits
ReferencesLink to record
Permanent link

Direct link