Change search
ReferencesLink to record
Permanent link

Direct link
Reconstruction and Finite Element Mesh Generation of Abdominal Aortic Aneurysms From Computerized Tomography Angiography Data With Minimal User Interactions
KTH, School of Engineering Sciences (SCI), Solid Mechanics (Dept.).
2010 (English)In: IEEE Transactions on Medical Imaging, ISSN 0278-0062, E-ISSN 1558-254X, Vol. 29, no 4, 1022-1028 p.Article in journal (Refereed) Published
Abstract [en]

Evaluating rupture risk of abdominal aortic aneurysms is critically important in reducing related mortality without unnecessarily increasing the rate of elective repair. According to the current clinical practice aneurysm rupture risk is (mainly) estimated from its maximum diameter and/or expansion rate; an approach motivated from statistics but known to fail often in individuals. In contrast, recent research demonstrated that patient specific biomechanical simulations can provide more reliable diagnostic parameters, however current structural model development is cumbersome and time consuming. This paper used 2D and 3D deformable models to reconstruct aneurysms from computerized tomography angiography data with minimal user interactions. In particular, formulations of frames and shells, as known from structural mechanics, were used to define deformable modes, which in turn allowed a direct mechanical interpretation of the applied set of reconstruction parameters. Likewise, a parallel finite element implementation of the models allows the segmentation of clinical cases on standard personal computers within a few minutes. The particular topology of the applied 3D deformable models supports a fast and simple hexahedral-dominated meshing of the arising generally polyhedral domain. The variability of the derived segmentations (luminal: 0.50(SD 0.19) mm; exterior 0.89(SD 0.45) mm) with respect to large variations in elastic properties of the deformable models was in the range of the differences between manual segmentations as performed by experts (luminal: 0.57(SD 0.24) mm; exterior: 0.77(SD 0.58) mm), and was particularly independent from the algorithm's initialization. The proposed interaction of deformable models and mesh generation defines finite element meshes suitable to perform accurate and efficient structural analysis of the aneurysm using mixed finite element formulations.

Place, publisher, year, edition, pages
2010. Vol. 29, no 4, 1022-1028 p.
Keyword [en]
Abdominal aortic aneurysm (AAA), finite element method (FEM), hexahedral, image segmentation, meshing, rupture risk, wall stress, intraluminal thrombus, failure properties, cta images, rupture, segmentation, methodology, diameter, models, risk
National Category
Computer Science
URN: urn:nbn:se:kth:diva-19352DOI: 10.1109/tmi.2009.2039579ISI: 000276091000005ScopusID: 2-s2.0-77950410742OAI: diva2:337399
Swedish Research Council, 2006-7568
QC 20100525Available from: 2010-08-05 Created: 2010-08-05 Last updated: 2011-10-04Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Gasser, T. Christian
By organisation
Solid Mechanics (Dept.)
In the same journal
IEEE Transactions on Medical Imaging
Computer Science

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 45 hits
ReferencesLink to record
Permanent link

Direct link