Change search
ReferencesLink to record
Permanent link

Direct link
Low-frequency low-field magnetic susceptibility of ferritin and hemosiderin
KTH, Superseded Departments, Materials Science and Engineering.ORCID iD: 0000-0003-2170-0076
Show others and affiliations
2000 (English)In: Biochimica et Biophysica Acta - Molecular Basis of Disease, ISSN 0925-4439, Vol. 1500, no 2, 186-196 p.Article in journal (Refereed) Published
Abstract [en]

Low-frequency low-field magnetic susceptibility measurements were made on four samples of mammalian tissue iron oxide deposits. The samples comprised: (1) horse spleen ferritin; (') dugong liver hemosiderin; (3) thalassemic human spleen ferritin; and (4) crude thalassemic human spleen hemosiderin. These samples were chosen because Mossbauer spectroscopic measurements on the samples indicated that they exemplified the variation in magnetic and mineral structure found in mammalian tissue iron oxide deposits. The AC-magnetic susceptometry yielded information on the magnetization kinetics of the four samples indicating samples 1, 2, and 3 to be superparamagnetic with values of around 10(11) s(-1) for the preexponential frequency factor in the Neel-Arrhenius equation and values for characteristic magnetic anisotropy energy barriers in the range 250-400 K. Sample 4 was indicated to he paramagnetic at all temperatures above 1.3 K. The AC-magnetic susceptometry data also indicated a larger magnetic anisotropy energy distribution in the dugong liver sample compared with samples 1 and 3 in agreement with previous Mossbauer spectroscopic data on these samples. At temperatures below 200 K, samples 1-3 exhibited Curie-Weiss law behavior, indicating weak particle-particle interactions tending to favor antiparallel alignment of the particle magnetic moments. These interactions were strongest for the dugong liver hemosiderin. possibly reflecting the smaller separation between mineral particles in this sample. This is the first magnetic susceptometry study of hemosiderin iron deposits and demonstrates that the AC-magnetic susceptometry technique is a fast and informative method of studying such tissue iron oxide deposits.

Place, publisher, year, edition, pages
2000. Vol. 1500, no 2, 186-196 p.
Keyword [en]
AC-magnetic susceptibility, ferritin, hemosiderin, superparamagnetism, iron oxide, Mossbauer spectroscopy, iron-oxide deposits, thalassemia hemoglobin-e, mossbauer-spectroscopy, overload diseases, cores, tissues, spleen, limpet
URN: urn:nbn:se:kth:diva-19569ISI: 000085469800005OAI: diva2:338261
QC 20100525Available from: 2010-08-10 Created: 2010-08-10Bibliographically approved

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Ström, Valter
By organisation
Materials Science and Engineering
In the same journal
Biochimica et Biophysica Acta - Molecular Basis of Disease

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 24 hits
ReferencesLink to record
Permanent link

Direct link