Resolution and noise properties of scintillator coated X-ray detectors
KTH, Superseded Departments, Microelectronics and Information Technology, IMIT.
2001 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 466, no 1, 178-182 p.Article in journal (Refereed) Published
Abstract [en]

The imaging properties of X-ray pixel detectors depend on the quantum efficiency of X-rays, the generated signal of each X-ray photon and the distribution of the generated signal between pixels. In a scintillator coated device the signal is generated both by X-ray photons captured in the scintillator and by X-ray photons captured directly in the semiconductor. The Signal-to-Noise Ratio in the image is then a function of the number of photons captured in each of these processes and the yield, in terms of electron-hole pairs produced in the semiconductor, of each process. The spatial resolution is primarily determined by the light spreading within the scintillator. In a pure semiconductor detector the signal is generated by one process only. The Signal-to-Noise Ratio in the image is proportional to the number of X-ray photons captured within the sensitive layer. The spatial resolution is affected by the initial charge cloud generated in the semiconductor and any diffusion of carriers between the point of interaction and the readout electrode. In this paper we discuss the theory underlying the imaging properties of scintillator coated X-ray imaging detectors. The model is verified by simulations using MCNP and by experimental results. The results from the two-layer detector are compared with those from a pure semiconductor X-ray detector.

Place, publisher, year, edition, pages
2001. Vol. 466, no 1, 178-182 p.
Keyword [en]
X-ray, detector, scintillator, signal-to-noise ratio, simulation, sensors
Identifiers
URN: urn:nbn:se:kth:diva-20777ISI: 000169789200027OAI: oai:DiVA.org:kth-20777DiVA: diva2:339474
Note
QC 20100525Available from: 2010-08-10 Created: 2010-08-10 Last updated: 2017-12-12Bibliographically approved

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Petersson, C. Sture
By organisation
Microelectronics and Information Technology, IMIT
In the same journal
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 32 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf