Change search
ReferencesLink to record
Permanent link

Direct link
Characterization of micromachined spiked biopotential electrodes
KTH, Superseded Departments, Signals, Sensors and Systems.ORCID iD: 0000-0001-9552-4234
2002 (English)In: IEEE Transactions on Biomedical Engineering, ISSN 0018-9294, E-ISSN 1558-2531, Vol. 49, no 6, 597-604 p.Article in journal (Refereed) Published
Abstract [en]

We present the characterization of dry spiked biopotential electrodes and test their suitability to be used in anesthesia monitoring systems based on the measurement of electroencephalographic signals. The spiked electrode consists of an array of microneedles penetrating the outer skin layers. We found a significant dependency of the electrode-skin-electrode impedance (ESEI) on the electrode size (i.e., the number of spikes) and the coating material of the spikes. Electrodes larger than 3 x 3 mm(2) coated with Ag-AgCl have sufficiently low ESEI to be well suited for electroencephalograph (EEG) recordings. The maximum measured ESEI was 4.24 kOmega and 87 kOmega, at 1 kHz and 0.6 Hz, respectively. The minimum ESEI was 0.65 kOmega an 16 kOmega, at the same frequencies. The ESEI of spiked electrodes is stable over an extended period of time. The arithmetic mean of the generated dc offset voltage is 11.8 mV immediately after application on the skin and 9.8 mV after 20-30 min. A spectral study of the generated potential difference revealed that the ac part was unstable at frequencies below approximately 0.8 Hz. Thus, the signal does not interfere with a number of clinical applications using real-time EEG. Comparing raw EEG recordings of the spiked electrode with commercial Zipprep electrodes showed that both signals were similar. Due to the mechanical strength of the silicon microneedles and the fact that neither skin preparation nor electrolytic gel is required, use of the spiked electrode is convenient. The spiked electrode is very comfortable for the patient.

Place, publisher, year, edition, pages
2002. Vol. 49, no 6, 597-604 p.
Keyword [en]
biopotential electrode, dry electrode, EEG, microneedle, microspike
URN: urn:nbn:se:kth:diva-21557DOI: 10.1109/TBME.2002.1001974ISI: 000175711000011OAI: diva2:340255
QC 20100525Available from: 2010-08-10 Created: 2010-08-10Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Stemme, Göran
By organisation
Signals, Sensors and Systems
In the same journal
IEEE Transactions on Biomedical Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 28 hits
ReferencesLink to record
Permanent link

Direct link