A new edge-detected lift force flow sensor
KTH, Superseded Departments, Signals, Sensors and Systems.ORCID iD: 0000-0001-9552-4234
2003 (English)In: Journal of microelectromechanical systems, ISSN 1057-7157, E-ISSN 1941-0158, Vol. 12, no 3, 344-354 p.Article in journal (Refereed) Published
Abstract [en]

A lift force gas flow sensor which uses the force normal to the fluid flow to measure the flow velocity has recently been introduced. Two thin plates mounted at an angle are deflected when they are subjected to fluid flow. For most mechanical flow sensors the flow sensitivity is closely connected to the time response. A weaker structure gives higher flow sensitivity but a lower natural frequency, i.e., a slower response time. The lift force sensor is designed for measurements of respiratory gas flow in ventilators, where, in addition to low flow restriction, both high sensitivity and fast response are required. A new type of suspension has now been realized for the lift force flow sensor. The detection is separated from the suspension of the airfoil plate with the strain gauges placed on separate detector beams. This leads to separate parameters for optimization of the lift force concept with independent control of flow sensitivity and natural frequency. This paper presents an analytical model, simulations and measurements on the new structure. The new edge-detected sensor has been experimentally evaluated for different lengths (100-600 mum), widths (20-100 mum) and thicknesses (8-20 mum) of the detector beams. In accordance with the theory, the measurements show that the new structure has approximately three times the natural frequency of the old, center detected structure and similar or improved flow sensitivity. The evaluation has also resulted in a design scheme for optimal performance. A flow sensitivity of 0.65 muV/V/(l/min)(2) has been obtained for the best edge-detected sensor with a natural frequency of 3.2 kHz.

Place, publisher, year, edition, pages
2003. Vol. 12, no 3, 344-354 p.
Identifiers
URN: urn:nbn:se:kth:diva-22565DOI: 10.1109/jmems.2002.807479ISI: 000183356300014OAI: oai:DiVA.org:kth-22565DiVA: diva2:341263
Note
QC 20100525Available from: 2010-08-10 Created: 2010-08-10 Last updated: 2017-12-12Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Stemme, Göran

Search in DiVA

By author/editor
Stemme, Göran
By organisation
Signals, Sensors and Systems
In the same journal
Journal of microelectromechanical systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 21 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf