A method to maintain wafer alignment precision during adhesive wafer bonding
KTH, Superseded Departments, Signals, Sensors and Systems.ORCID iD: 0000-0002-0525-8647
KTH, Superseded Departments, Signals, Sensors and Systems.ORCID iD: 0000-0001-9552-4234
2003 (English)In: Sensors and Actuators A-Physical, ISSN 0924-4247, E-ISSN 1873-3069, Vol. 107, no 3, 273-278 p.Article in journal (Refereed) Published
Abstract [en]

In this paper, a novel method is presented that prevents aligned wafers from shifting relative to each other during adhesive bonding. The attainable pre-bond wafer alignment accuracy on commercially available bonding equipment is typically 2-5 mum. However, in adhesive wafer bonding, the intermediate adhesive material must exist in a liquid-like state to wet the wafer surfaces and thereby achieve bonding. When pressing the wafers together with the bond chucks during the bonding process it is practically inevitable that shear forces occur, which act in parallel to the bond line. The intermediate liquid adhesive material cannot counteract the shear forces, thus, the wafers move relative to each other. Consequently, the achievable alignment accuracy in adhesive wafer bonding is typically less than 15 mum using commercial bonding equipment. A novel method has been developed that utilises structures at the wafer surfaces to provide areas with solid-state material contact between the two wafers during the bonding process. The resulting frictional forces prevent the wafers from shifting relative to each other during the time the intermediate adhesive material is in a liquid state. Thus, the pre-bond alignment accuracy of 2-5 mum can be maintained during adhesive wafer bonding using standard wafer bonding equipment as compared to a wafer alignment accuracy of 15-50 mum when no frictional structures are used.

Place, publisher, year, edition, pages
2003. Vol. 107, no 3, 273-278 p.
Keyword [en]
alignment, wafer alignment, wafer bond equipment, adhesive bonding, wafer bonding, polymer bonding
Identifiers
URN: urn:nbn:se:kth:diva-22933DOI: 10.1016/s0924-4247(03)00356-xISI: 000186376400008OAI: oai:DiVA.org:kth-22933DiVA: diva2:341631
Note
QC 20100525Available from: 2010-08-10 Created: 2010-08-10 Last updated: 2017-12-12Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Niklaus, FrankStemme, Göran

Search in DiVA

By author/editor
Niklaus, FrankStemme, Göran
By organisation
Signals, Sensors and Systems
In the same journal
Sensors and Actuators A-Physical

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 30 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf