Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Stability of acetabular axis after total hip arthroplasty, repeatability using CT and a semiautomated program for volume fusion
Karolinska Institute, Department of Molecular Medicine and Surgery.
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology.
Karolinska Institute, Department of Molecular Medicine and Surgery.
New York University, Department of Radiology. (Nuclear Medicine)
Show others and affiliations
2003 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 44, no 6, 653-661 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: To validate a CT method for detecting changes in acetabular cup orientation after THA. Material and Methods: 26 CT examinations were obtained from a pelvic model with an uncemented acetabular cup. The model position was altered between acquisitions, but the cup axis angle vis-a-vis the pelvis was maintained. Data sets were combined into 37 pairs, each containing a unique positioning error. The pelvi in different examinations were fused, creating transformed volumes. Landmarks corresponding to the cup before and after fusion were placed interactively by two independent examiners. The orientation of the acetabular axis was calculated for each volume and compared across volumes. Results: Before fusion the mean angle error between the acetabular axes was 4.17degrees (SD +/- 1.95degrees). After fusion the mean angle error was 0.36degrees (SD +/- 0.17). The 95% repeatability limits were below 0.7degrees. There was no significant interobserver difference. Analysis of the cup landmarking pattern by condition numbers and individual landmark errors showed stability. Conclusion: Non-invasive fusion of CT volumes and a stable landmarking pattern for the acetabular cup outperforms routine plain radiography in detecting changes in the orientation of the acetabular axis over time. The method delivers both visual and numerical output and could be used in clinical practice.

Place, publisher, year, edition, pages
2003. Vol. 44, no 6, 653-661 p.
Keyword [en]
CT, hip prosthesis, volume fusion, migration, model study, component migration, ebra
National Category
Orthopedics Radiology, Nuclear Medicine and Medical Imaging
Research subject
SRA - ICT
Identifiers
URN: urn:nbn:se:kth:diva-22971DOI: 10.1046/j.1600-0455.2003.00153.xISI: 000186654000013OAI: oai:DiVA.org:kth-22971DiVA: diva2:341669
Note
QC 20100525 NR 20140804Available from: 2010-08-10 Created: 2010-08-10 Last updated: 2017-12-12Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Maguire Jr., Gerald Q.

Search in DiVA

By author/editor
Maguire Jr., Gerald Q.Svensson, Lars E.
By organisation
Microelectronics and Information Technology, IMITMathematics (Dept.)
In the same journal
Acta Radiologica
OrthopedicsRadiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 131 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf