Change search
ReferencesLink to record
Permanent link

Direct link
Energy savings versus year‐round production in a small hydroponic system for wastewater treatment.
KTH, School of Biotechnology (BIO).
KTH, School of Biotechnology (BIO).
(English)In: Water Science and Technology, ISSN 0273-1223Article in journal (Other academic) Submitted
National Category
Microbiology in the medical area
URN: urn:nbn:se:kth:diva-25262OAI: diva2:356851
QS 20120328Available from: 2010-10-14 Created: 2010-10-14 Last updated: 2012-03-28Bibliographically approved
In thesis
1. Treatment of domestic wastewater using microbiological processes and hydroponics in Sweden
Open this publication in new window or tab >>Treatment of domestic wastewater using microbiological processes and hydroponics in Sweden
2005 (English)Doctoral thesis, comprehensive summary (Other scientific)
Abstract [en]

Conventional end-of-pipe solutions for wastewater treatment have been criticized from a sustainable view-point, in particular regarding recycling of nutrients. The integration of hydroponic cultivation into a wastewater treatment system has been proposed as an ecological alternative, where nutrients can be removed from the wastewater through plant uptake; however, cultivation of plants in a temperate climate, such as Sweden, implies that additional energy is needed during the colder and darker period. Thus, treatment capacity, additional energy usage and potential value of products are important aspects considering the applicability of hydroponic wastewater treatment in Sweden.

To enable the investigation of hydroponic wastewater treatment, a pilot plant was constructed in a greenhouse located at Överjärva gård, Solna, Sweden. The pilot plant consisted of several steps, including conventional biological processes, hydroponics, algal treatment and sand filters. The system treated around 0.56-0.85 m3 domestic wastewater from the Överjärva gård area per day. The experimental protocol, performed in an average of twice per week over a period of three years, included analysis and measurements of water quality and physical parameters. In addition, two studies were performed when daily samples were analysed during a period of two-three weeks. Furthermore, the removal of pathogens in the system, and the microbial composition in the first hydroponic tank were investigated.

Inflow concentrations were in an average of around 475 mg COD/L, 100 mg Tot-N/L and 12 mg Tot-P/L. The results show that 85-90% of COD was removed in the system. Complete nitrification was achieved in the hydroponic tanks. Denitrification, by means of pre-denitrification, occurred in the first anoxic tank. With a recycle ratio of 2.26, the achieved nitrogen removal in the system was around 72%. Approximately 4% of the removed amount of nitrogen was credited to plant uptake during the active growth period. Phosphorus was removed by adsorption in the anoxic tank and sand filters, natural chemical precipitation in the algal step induced by the high pH, and assimilation in plants, bacteria and algae. The main removal occurred in the algal step. In total, 47% of the amount of phosphorus was removed. Significant recycling of nitrogen and phosphorus through harvested biomass has not been shown. The indicators analysed for pathogen removal showed an achieved effluent quality comparable to, or better than, for conventional secondary treatment. The microbial composition was comparable to other nitrifying biological systems. The most abundant phyla were Betaproteobacteria and Planctomycetes.

In Sweden, a hydroponic system is restricted to greenhouse applications, and the necessary amount of additional energy is related to geographic location. In conclusion, hydroponic systems are not recommended too far north, unless products are identified that will justify the increased energy usage. The potential for hydroponic treatment systems in Sweden lies in small decentralized systems where the greenness of the system and the possible products are considered as advantages for the users.

Place, publisher, year, edition, pages
Stockholm: KTH, 2005. iv, 56 p.
Microbiology, biological, hydroponics, microbial composition, nitrogen, organic matter, phosphorus, small scale, theoretical energy requirements, wastewater treatment., Mikrobiologi
National Category
urn:nbn:se:kth:diva-183 (URN)91-7178-030-0 (ISBN)
Public defence
2005-05-18, Oskar Kleins auditorium, AlbaNova, Roslagstullsbacken 21, Stockholm, 14:00
QC 20101014Available from: 2005-04-28 Created: 2005-04-28 Last updated: 2010-10-14Bibliographically approved

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Norström, AnnaLa Cour Jansen, JesDalhammar, Gunnel
By organisation
School of Biotechnology (BIO)
In the same journal
Water Science and Technology
Microbiology in the medical area

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 64 hits
ReferencesLink to record
Permanent link

Direct link