Change search
ReferencesLink to record
Permanent link

Direct link
Computed tomography analysis of radiostereometric data to determine flexion axes after total joint replacement: Application to the elbow joint
Karolinska Institute, Department of Molecular Medicine and Surgery, Section of Orthopaedics and Sports Medicine.
Karolinska Institute, Department of Molecular Medicine and Surgery.
Karolinska Institute, Department of Molecular Medicine and Surgery.
New York University, Department of Radiology. (Nuclear Medicine)
Show others and affiliations
2010 (English)In: Journal of Biomechanics, ISSN 0021-9290, E-ISSN 1873-2380, Vol. 43, no 10, 1947-1952 p.Article in journal (Refereed) Published
Abstract [en]

Kinematic analysis for in vivo assessment of elbow endoprostheses requires knowledge of the exact positions of motion axes relative to bony landmarks or the prosthesis. A prosthesis-based reference system is required for comparison between individuals and studies. The primary aim of this study was to further develop an earlier described algorithm for fusion of radiostereometric analysis (RSA) data and data obtained in 3D computed tomography (CT) for application to the elbow after total joint replacement. The secondary aim was to propose a method for marking of prostheses in 3D CT, enabling definition of a prosthesis-based reference system. Six patients with elbow endoprostheses were investigated. The fusion of data made it possible to visualize the motion axes in relation to the prostheses in the 3D CT volume. The differences between two repeated positioning repetitions of the longitudinal prosthesis axis were less than 0.6 degrees in the frontal and sagittal planes. Corresponding values for the transverse axis were less than 0.6 degrees in the frontal and less than 1.4 degrees (in four out of six less than 0.6 degrees) in the horizontal plane. This study shows that by fusion of CT and RSA data it is possible to determine the accurate position of the flexion axes of the elbow joint after total joint replacement in vivo. The proposed method for implant marking and registration of reference axes enables comparison of prosthesis function between patients and studies.

Place, publisher, year, edition, pages
2010. Vol. 43, no 10, 1947-1952 p.
Keyword [en]
Radiostereometric analysis, 3D computed tomography, Joint visualization, Elbow prosthesis, Elbow flexion axes
National Category
Computer and Information Science
URN: urn:nbn:se:kth:diva-25858DOI: 10.1016/j.jbiomech.2010.03.016ISI: 000280313300015ScopusID: 2-s2.0-77954143148OAI: diva2:360259

QC 20150630

Available from: 2010-11-02 Created: 2010-11-02 Last updated: 2015-06-30Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Maguire Jr., Gerald Q.
By organisation
Communication Systems, CoS
In the same journal
Journal of Biomechanics
Computer and Information Science

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 152 hits
ReferencesLink to record
Permanent link

Direct link