Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Analysis of Bias in the Apparent Correlation Coefficient Between Image Pairs Corrupted by Severe Noise
KTH, School of Computer Science and Communication (CSC), Numerical Analysis and Computer Science, NADA.
2010 (English)In: Journal of Mathematical Imaging and Vision, ISSN 0924-9907, E-ISSN 1573-7683, Vol. 37, no 3, 204-219 p.Article in journal (Refereed) Published
Abstract [en]

The correlation coefficient r is a measure of similarity used to compare regions of interest in image pairs. In fluorescence microscopy there is a basic tradeoff between the degree of image noise and the frequency with which images can be acquired and therefore the ability to follow dynamic events. The correlation coefficient r is commonly used in fluorescence microscopy for colocalization measurements, when the relative distributions of two fluorophores are of interest. Unfortunately, r is known to be biased understating the true correlation when noise is present. A better measure of correlation is needed. This article analyses the expected value of r and comes up with a procedure for evaluating the bias of r, expected value formulas. A Taylor series of so-called invariant factors is analyzed in detail. These formulas indicate ways to correct r and thereby obtain a corrected value free from the influence of noise that is on average accurate (unbiased). One possible correction is the attenuated corrected correlation coefficient R, introduced heuristically by Spearman (in Am. J. Psychol. 15:72-101, 1904). An ideal correction formula in terms of expected values is derived. For large samples R tends towards the ideal correction formula and the true noise-free correlation. Correlation measurements using simulation based on the types of noise found in fluorescence microscopy images illustrate both the power of the method and the variance of R. We conclude that the correction formula is valid and is particularly useful for making correct analyses from very noisy datasets.

Place, publisher, year, edition, pages
2010. Vol. 37, no 3, 204-219 p.
Keyword [en]
Correction correlation coefficient, Severely degraded images
National Category
Computer Vision and Robotics (Autonomous Systems)
Identifiers
URN: urn:nbn:se:kth:diva-27502DOI: 10.1007/s10851-010-0200-zISI: 000278580600002Scopus ID: 2-s2.0-77954958740OAI: oai:DiVA.org:kth-27502DiVA: diva2:386100
Funder
Swedish Research Council, 621-2004-2948
Note
QC 20110112Available from: 2011-01-12 Created: 2010-12-13 Last updated: 2017-12-11Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Bergholm, Fredrik
By organisation
Numerical Analysis and Computer Science, NADA
In the same journal
Journal of Mathematical Imaging and Vision
Computer Vision and Robotics (Autonomous Systems)

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 60 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf