Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
On the assessment of the impact of a conventional HVDC on a test power system
KTH, School of Electrical Engineering (EES), Electric Power Systems.ORCID iD: 0000-0002-2356-4795
KTH, School of Electrical Engineering (EES), Electric Power Systems.
KTH, School of Electrical Engineering (EES), Electric Power Systems.ORCID iD: 0000-0002-8189-2420
2007 (English)In: 2007 IREP SYMPOSIUM- BULK POWER SYSTEM DYNAMICS AND CONTROL: VII REVITALIZING OPERATIONAL RELIABLITY, VOLS 1 AND 2, NEW YORK: IEEE , 2007, 58-62 p.Conference paper, Published paper (Refereed)
Abstract [en]

There are several possibilities to improve the first swing transient stability in a power system. One adequate option is to use the high controllability of the HVDC if HVDC is available in the system. This paper presents a control strategy for HVDC to improve the first swing transient. The strategy controls the power through the HVDC to make the system more transient stable during disturbances. The proposed control strategy consists of the PD-controller and feed-forward control, the use of a PD-controller is appropriate since it has the property of fast response. To improve the first swing oscillation even more the feed-forward control is used, since the behavior of system due to the disconnection is known. Two bench mark power systems are subjected to large disturbances to examine the effectiveness of the proposed strategy. Depending on how the power through the HVDC is controlled the transients damp differently. The PD-controller works well and damps the first swing oscillation transient so the system remains stable. When a power step also is applied after the line is disconnected, the transient swing becomes lower and the behaviour of the system is better. There is also a possibility to improve the first swing oscillation even more, by applying a power step through the HVDC which will compensate for the lack of power due to the disconnection of the line caused by the disturbance.

Place, publisher, year, edition, pages
NEW YORK: IEEE , 2007. 58-62 p.
Keyword [en]
Dynamics, Electric power systems, Electric power transmission networks, Power transmission, Reliability
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:kth:diva-36700DOI: 10.1109/IREP.2007.4410514ISI: 000256074700007Scopus ID: 2-s2.0-47949115236ISBN: 978-1-4244-1518-2 (print)OAI: oai:DiVA.org:kth-36700DiVA: diva2:431010
Conference
iREP Symposium on Bulk Power System Dynamics and Control - VII Revitalizing Operational Reliability Charleston, SC, AUG 19-24, 2007
Note
QC 20110913Available from: 2011-07-14 Created: 2011-07-13 Last updated: 2011-12-19Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Authority records BETA

Söder, Lennart

Search in DiVA

By author/editor
Eriksson, RobertKnazkins, ValerijsSöder, Lennart
By organisation
Electric Power Systems
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 72 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf