Utvecklandet av en dynamisk handortos i en klinisk miljö
KTH, School of Industrial Engineering and Management (ITM), Machine Design (Dept.).
2011 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
The Conceptualization of a Novel Splint in a Clinical Setting (English)
Abstract [sv]

Sammanfattning

Sister Kenny Rehabilitation Institute i Minneapolis är en sjukhusinstitution, känd för sin innovativa rehabiliteringsteknik och sjukhusutrustning sedan långt tillbaka i tiden.

Projektet för det här examensarbetet utfördes inom Sister Kenny Research Center, forskningscentret för institutet. Det som öppnade upp för projektet var en vilja att göra en ny, radikal innovation inom området dynamiska ortoser. Fokuset låg på människor som drabbats av stroke, och därför fått en halvsidesförlamning i ena handen.

Lösningar med drag-system för att räta ut handens fingrar kunde hittas i befintliga ortoser för denna grupp människor. I likhet med de dragsystem som tillämpas i annan utrustning inom sjukhusmiljön var dessa generellt klumpiga och inte särskilt funktionella.

Målet blev därför att skapa en bättre ortos som kunde möjliggöra en längre användningstid, och ett användande i miljöer utanför sjukhuset.

Ett kliniskt innovationsteam skapades, för att ta fram nya koncept, och för att garantera att både användarens och konsumentens röst blev hörd mitt i innovationsprocessen.

Bakgrundsstudier, observationer och intervjuer utfördes för att reda ut var de verkliga problemen låg, och för att separera det nya konceptet från existerande.

Genom användandet av diverse kreativa verktyg tog teamet fram fem koncept. På ett av dessa utvecklade de finger-element, transmission och reglage-delar, som skulle utgöra en mer skonsam och användarvänlig ortos.

Resultatet av projektet blev en ”sen-härmande” ortos gjord av resårband, knutna till olika delar av fingret. Anslutna reglage var sedan placerade på underarmen, så att användaren kunde spänna ut handen gradvis.

De unika egenskaper som ortosen har skulle kunna tillämpas i bättre framtida produkter och även i patentansökningar inom området dynamiska ortoser.

Abstract [en]

Abstract

Sister Kenny Rehabilitation Institute in Minneapolis is a hospital department historically known for its innovative physical therapy and technology. The project for this thesis took place at Sister Kenny Research Center, the research division of this Institute.

The aim was to initiate a project for radical innovation within the area of dynamic splints. The focus group was stroke survivors affected by hemi paresis in their hands.

Solutions with built-in pulley systems to support the fingers of the hand could be found in various existing devices for this focus group. As with pulley systems in other applications in the hospital environment, these devices were generally bulky and not very functional.

The goal, for this matter, was to create a better splint that allowed the user to wear in for a longer period of time and to make it useful in non-hospital environments.

A clinical innovation team was established to come up with a concept for this goal and to assure that the voice of both end-user and costumer was reflected in the innovation process.

Background studies, observations and interviews were made to determine what the real problems were, and to separate the new concept from others.

With a high expectancy and the use of creative tools, the team came up with five favorite concepts. With one of these, they developed new finger-elements, transmission and adjustment parts to fit the goal better.

The outcome was a tendon-mimicking device made of elastic springs in rubber connected to different finger parts. Connecting adjustments were placed on the underarm, so that the user could extend the hand gradually when using it.

Many of the goals that the team had initially were reached, and the unique features of the concept could likely fit in future products, or in a patent application.

Place, publisher, year, edition, pages
2011. , 57 p.
Series
MMK 2011:50 MCE 250
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-39802OAI: oai:DiVA.org:kth-39802DiVA: diva2:440524
Uppsok
Technology
Supervisors
Examiners
Available from: 2011-11-28 Created: 2011-09-13 Last updated: 2011-11-28Bibliographically approved

Open Access in DiVA

The Conceptualization of a Novel Splint in a Clinical Setting(1920 kB)411 downloads
File information
File name FULLTEXT01.pdfFile size 1920 kBChecksum SHA-512
3de9d60b81fe8a817a9e4929009ed32e6a37bc4a5064e8c5cf4dd3880802b4c70eeadc1341aaced7e57d7e6c8a8bfda510c6b98f73c173b99297c4fbc9e927e5
Type fulltextMimetype application/pdf

By organisation
Machine Design (Dept.)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 411 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 160 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf