Performance evaluation of a sub-millimeter spectrally resolved CT system on pediatric imaging tasks: a simulation
KTH, School of Engineering Sciences (SCI), Physics, Medical Imaging.ORCID iD: 0000-0001-7253-0164
KTH, School of Engineering Sciences (SCI), Physics, Medical Imaging.
KTH, School of Engineering Sciences (SCI), Physics, Medical Imaging.
2011 (English)In: MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING / [ed] Pelc, NJ; Samei, E; Nishikawa, RM, 2011, Vol. 7961Conference paper (Refereed)
Abstract [en]

We are developing a photon counting silicon strip detector with 0.4x0.5 mm(2) square detector elements for clinical CT applications. Except the somewhat limited detection efficiency at higher kVp's the largest discrepancies from ideal spectral behavior have been shown to be Compton interactions in the detector combined with electronic noise. Using the framework of cascaded systems analysis, we reconstruct the 3D MTF and NPS of a silicon strip detector using "optimal" projection based weighting, including the influence of scatter and charge sharing inside the detector. We compare the reconstructed noise and signal characteristics with a reconstructed 3D MTF and NPS of an ideal energy integrating detector by calculating the detectability index for several clinically relevant imaging task. This work demonstrates that although the detection efficiency of the silicon detector rapidly drops for the acceleration voltages encountered in clinical computed tomography practice and the high fraction of Compton interactions due to the low atomic number, silicon detectors can perform on par with ideal energy integrating detectors for routine imaging tasks contaning low frequency components. For imaging task containing high frequency components, silicon detectors can perform approximately 1.4 - 1.8 times better than a fully ideal energy integrating system with unity detection, no scatter or charge sharing inside the detector and 1x1 mm(2) square detector elements.

Place, publisher, year, edition, pages
2011. Vol. 7961
, Proceedings of SPIE, ISSN 0277-786X ; 7961
Keyword [en]
spectral CT, silicon detector, cascaded systems analysis
National Category
Physical Sciences
URN: urn:nbn:se:kth:diva-41311DOI: 10.1117/12.877826ISI: 000294178500199ScopusID: 2-s2.0-79955759362OAI: diva2:443734
Conference on Medical Imaging 2011 - Physics of Medical Imaging, Lake Buena Vista, FL, FEB 13-17, 2011
Available from: 2011-09-26 Created: 2011-09-26 Last updated: 2011-09-26Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Yveborg, MoaDanielsson, Mats E.Bornefalk, Hans
By organisation
Medical Imaging
Physical Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 22 hits
ReferencesLink to record
Permanent link

Direct link