Warping CT scans from nontreatment to treatment position
New York University.
New York University.
Show others and affiliations
1997 (English)In: Radiation oncology investigations (Print), ISSN 1065-7541, E-ISSN 1520-6823, Vol. 5, no 4, 206-212 p.Article in journal (Refereed) Published
Abstract [en]

This paper describes a cost-effective technique that optimally utilizes all available diagnostic studies for three-dimensional treatment planning. A simulator unit modified to produce cross-sectional images {(simulator-CT} unit) is used to create a reference data set with the patient in the treatment position. Registration software (qsh) brings other diagnostic studies into agreement with this reference data set. Two cases are presented as examples of the use of this technique. Registration of abdominal scans from the same patient demonstrates the warping of a nontreatment position study to the treatment position. The second case is based on paired data sets through the head, in which the diagnostic study was obtained by using a gantry tilt to follow the base of the skull and to avoid sections passing through the teeth. The registration software provides a method for combining diagnostic studies into a single "master" data set. The success of the transformation depends on the operator's ability to identify corresponding anatomic landmarks for different data sets and on the magnitude of the variation in the patient's position from one procedure to the next. Limitations in image quality and the number of cross-sections obtainable from a {simulator-CT} unit can be partially overcome by using the described technique. Thus, the information contained in nontreatment position diagnostic tests can be used accurately for treatment planning at limited cost.

Place, publisher, year, edition, pages
1997. Vol. 5, no 4, 206-212 p.
Keyword [en]
CT simulation, Image warping, Simulation CT, Three-dimensional treatment planning
National Category
Medical and Health Sciences
Research subject
SRA - ICT
Identifiers
URN: urn:nbn:se:kth:diva-46765DOI: 10.1002/(SICI)1520-6823(1997)5:4<206::AID-ROI6>3.0.CO;2-1PubMedID: 9327500OAI: oai:DiVA.org:kth-46765DiVA: diva2:454148
Note
QC 20111107Available from: 2011-11-05 Created: 2011-11-05 Last updated: 2017-12-08Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Maguire Jr., Gerald Q.

Search in DiVA

By author/editor
Maguire Jr., Gerald Q.
By organisation
Teleinformatics
In the same journal
Radiation oncology investigations (Print)
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 126 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf