AD5933-based electrical bioimpedance spectrometer: Towards textile-enabled applications
KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).ORCID iD: 0000-0002-6995-967X
KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
2011 (English)In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2011, Vol. 2011, 3282-3285 p.Conference paper, Published paper (Refereed)
Abstract [en]

Advances on System-On-Chip and Textile technology allows the development of Textile-enabled measurement instrumentation. Textile Electrodes (Textrodes) have been proven reliable for performing Electrical Bioimpedance Spectroscopy (EBIS) measurements, and the availability of a integrated circuit impedance spectrometer, the AD5933, has allowed the implementation of small size EBIS spectrometers. In this work an AD5933-based spectrometer has been implemented, and its performance on 2R1C circuits and for tetrapolar total right side EBIS measurements has been compared against the commercially available spectrometer SFB7. The study has been focused on the working upper frequency range and the estimation of the Cole parameters required for assessment of body fluid distribution: R(0) and R(∞). The results indicate that AD5933-based spectrometer implemented in this work can perform accurate impedance measurements well above the upper limits recommended in the datasheet. The AD5933-EBIS presents a good performance compared with the SFB7 on the 2R1C circuit and the total right side measurements, showing a smaller error in the resistance spectrum and small deviation error in the reactance when measuring over 270 kHz. The comparison on the Cole parameters estimation obtained with the SFB7 and the AD5933-based spectrometer exhibit a difference below 1% for the estimation of R(0) and R(∞). Consequently the overall measurement performance shown by the implemented AD5933-based spectrometer suggests its feasible use for EBIS measurements using dry Textrodes. This is of special relevance for the proliferation of EBI-based personalized health monitoring systems for patients that require to monitor the distribution of body fluids, like in dialysis.

Place, publisher, year, edition, pages
2011. Vol. 2011, 3282-3285 p.
National Category
Other Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-69633DOI: 10.1109/IEMBS.2011.6090891PubMedID: 22255040Scopus ID: 2-s2.0-84055212203OAI: oai:DiVA.org:kth-69633DiVA: diva2:485678
Conference
33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011; Boston, MA; 30 August 2011 through 3 September 2011
Note
QC 20120203Available from: 2012-01-29 Created: 2012-01-29 Last updated: 2017-05-17Bibliographically approved
In thesis
1. Textile-enabled Bioimpedance Instrumentation for Personalised Health Monitoring Applications
Open this publication in new window or tab >>Textile-enabled Bioimpedance Instrumentation for Personalised Health Monitoring Applications
2013 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

A growing number of factors, including the costs, technological advancements, an ageing population, and medical errors are leading industrialised countries to invest in research on alternative solutions to improving their health care systems and increasing patients’ life quality. Personal Health System (PHS) solutions envision the use of information and communication technologies that enable a paradigm shift from the traditional hospital-centred healthcare delivery model toward a preventive and person-centred approach. PHS offers the means to follow patient health using wearable, portable or implantable systems that offer ubiquitous, unobtrusive bio-data acquisition, allowing remote access to patient status and treatment monitoring.

Electrical Bioimpedance (EBI) technology is a non-invasive, quick and relatively affordable technique that can be used for assessing and monitoring different health conditions, e.g., body composition assessments for nutrition. EBI technology combined with state-of-the-art advances in sensor and textile technology are fostering the implementation of wearable bioimpedance monitors that use functional garments for the implementation of personalised healthcare applications.

This research studies the development of a portable EBI spectrometer that can use dry textile electrodes for the assessment of body composition for the purposes of clinical uses. The portable bioimpedance monitor has been developed using the latest advances in system-on-chip technology for bioimpedance spectroscopy instrumentation. The obtained portable spectrometer has been validated against commercial spectrometer that performs total body composition assessment using functional textrode garments.

The development of a portable Bioimpedance spectrometer using functional garments and dry textile electrodes for body composition assessment has been shown to be a feasible option. The availability of such measurement systems bring closer the real implementation of personalised healthcare systems.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2013. xvii, 48 p.
Series
Trita-STH : report, ISSN 1653-3836 ; 2013:1
Keyword
personal healthcare systems, bioimpedance, wearable, portable, monitoring, textrodes, body composition, chronic kidney disease, ambient assisting living, wireless sensor
National Category
Medical Engineering Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:kth:diva-120373 (URN)978-91-7501-702-0 (ISBN)
Presentation
2013-04-29, A608, University of Borås, Borås, 10:00 (English)
Opponent
Supervisors
Note

QC 20130405

Available from: 2013-04-05 Created: 2013-04-04 Last updated: 2013-04-05Bibliographically approved
2. Modular textile-enabled bioimpedance system for personalized health monitoring applications
Open this publication in new window or tab >>Modular textile-enabled bioimpedance system for personalized health monitoring applications
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

A growing number of factors, including costs, technological advancements, ageing populations, and medical errors, are leading industrialized countries to invest in research on alternative solutions to improve their health-care systems and increase patients’ quality of life. Personal health systems (PHS) examplify the use of information and communication technologies that enable a paradigm shift from the traditional hospital-centered healthcare delivery model toward a preventive and person-centered approach. PHS offer the means to monitor a patient’s health using wearable, portable or implantable systems that offer ubiquitous, unobtrusive biodata

acquisition, allowing remote monitoring of treatment and access to the patient’s status. Electrical bioimpedance (EBI) technology is non-invasive, quick and relatively affordable technique that can be used for assessing and monitoring different health conditions, e.g., body composition assessments for nutrition. When combined with state-of-the-art advances in sensors and textiles, EBI technologies are fostering the implementation of wearable bioimpedance monitors that use functional garments for personalized healthcare applications. This research work is

focused on the development of wearable EBI-based monitoring systems for ubiquitous health monitoring applications. The monitoring systems are built upon portable monitoring instrumentation and custom-made textile electrode garments.

Portable EBI-based monitors have been developed using the latest material technology and advances in system-on-chip technology. For instance, a portable EBI spectrometer has been validated against a commercial spectrometer for total body composition assessment using functional textile electrode garments. The development of wearable EBI-based monitoring units using functional garments and dry textile electrodes for body composition assessment and respiratory monitoring has been shown to be a feasible approach. The availability of these measurement systems indicates progress toward the real implementation of personalized healthcare systems.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2017. 89 p.
Series
TRITA-STH, 2017:6
Keyword
personal healthcare system, electrical bioimpedance, wearable sensors, pervasive monitoring, portable monitoring, body composition, chronic kidney disease, wireless sensor, ubiquitous, instrumentation
National Category
Medical Laboratory and Measurements Technologies
Research subject
Technology and Health
Identifiers
urn:nbn:se:kth:diva-207135 (URN)978-91-7729-377-4 (ISBN)
Public defence
2017-06-02, M402, Allégatan 1, Borås, 10:00 (English)
Opponent
Supervisors
Note

QC 20170517

Available from: 2017-05-17 Created: 2017-05-17 Last updated: 2017-05-17Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Authority records BETA

Seoane, Fernando

Search in DiVA

By author/editor
Ferreira, JavierSeoane, FernandoLindecrantz, Kaj
By organisation
Medical sensors, signals and systems (MSSS)
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 242 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf