Spectral distance for ARMA models applied to electroencephalogram for early detection of hypoxia
School of Engineering, Uiversity of Borås.
School of Engineering, University of Borås.
Department of Pediatrics, Queen Silvia Children's Hospital, Sahlgrenska University Hospital-Östra.
Department of Pediatrics, Queen Silvia Children's Hospital, Sahlgrenska University Hospital-Östra.
Show others and affiliations
2006 (English)In: Journal of Neural Engineering, ISSN 1741-2560, Vol. 3, no 3, 227-234 p.Article in journal (Refereed) Published
Abstract [en]

A novel measure of spectral distance is presented, which is inspired by the prediction residual parameter presented by Itakura in 1975, but derived from frequency domain data and extended to include autoregressive moving average (ARMA) models. This new algorithm is applied to electroencephalogram (EEG) data from newborn piglets exposed to hypoxia for the purpose of early detection of hypoxia. The performance is evaluated using parameters relevant for potential clinical use, and is found to outperform the Itakura distance, which has proved to be useful for this application. Additionally, we compare the performance with various algorithms previously used for the detection of hypoxia from EEG. Our results based on EEG from newborn piglets show that some detector statistics divert significantly from a reference period less than 2 min after the start of general hypoxia. Among these successful detectors, the proposed spectral distance is the only spectral-based parameter. It therefore appears that spectral changes due to hypoxia are best described by use of an ARMA-model-based spectral estimate, but the drawback of the presented method is high computational effort.

Place, publisher, year, edition, pages
2006. Vol. 3, no 3, 227-234 p.
National Category
Medical Engineering
URN: urn:nbn:se:kth:diva-75348DOI: 10.1088/1741-2560/3/3/005ISI: 000241268600007PubMedID: 16921206OAI: diva2:490967
QC 20120222Available from: 2012-02-06 Created: 2012-02-05 Last updated: 2012-02-22Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Lindecrantz, Kaj
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 22 hits
ReferencesLink to record
Permanent link

Direct link