Echo-guided presentation of the aortic valve minimises contrast exposure in transcatheter valve recipients
Linköping Heart Centre, University Hospital, Linköping University.
Linköping Heart Centre, University Hospital, Linköping University.
Linköping Heart Centre, University Hospital, Linköping University.
Linköping Heart Centre, University Hospital, Linköping University.
Show others and affiliations
2011 (English)In: Catheterization and cardiovascular interventions, ISSN 1522-1946, E-ISSN 1522-726X, Vol. 77, no 2, 272-275 p.Article in journal (Refereed) Published
Abstract [en]

OBJECTIVES: We have developed a method using transthoracic echocardiography in establishing optimal visualization of the aortic root, to reduce the amount of contrast medium used in each patient.

BACKGROUND: During transcatheter aortic valve implantation, it is necessary to obtain an optimal fluoroscopic projection for deployment of the valve showing the aortic ostium with the three cusps aligned in the beam direction. This may require repeat aortic root angiograms at this stage of the procedure with a high amount of contrast medium with a risk of detrimental influence on renal function.

METHODS: We studied the conventional way and an echo guided way to optimize visualisation of the aortic root. Echocardiography was used initially allowing easier alignment of the image intensifier with the transducer's direction.

RESULTS: Contrast volumes, radiation/fluoroscopy exposure times, and postoperative creatinine levels were significantly less in patients having the echo-guided orientation of the optimal fluoroscopic angles compared with patients treated with the conventional approach.

CONCLUSION: We present a user-friendly echo-guided method to facilitate fluoroscopy adjustment during transcatheter aortic valve implantation. In our series, the amounts of contrast medium and radiation have been significantly reduced, with a concomitant reduction in detrimental effects on renal function in the early postoperative phase.

Place, publisher, year, edition, pages
2011. Vol. 77, no 2, 272-275 p.
National Category
Medical Image Processing
Identifiers
URN: urn:nbn:se:kth:diva-85531DOI: 10.1002/ccd.22747ISI: 000287102500019PubMedID: 20824753OAI: oai:DiVA.org:kth-85531DiVA: diva2:499989
Note
QC 20120216Available from: 2012-02-13 Created: 2012-02-13 Last updated: 2017-12-07Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Janerot-Sjöberg, Birgitta

Search in DiVA

By author/editor
Janerot-Sjöberg, Birgitta
In the same journal
Catheterization and cardiovascular interventions
Medical Image Processing

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 36 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf