Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging.
KTH, School of Technology and Health (STH), Medical Engineering.ORCID iD: 0000-0003-1264-1254
Show others and affiliations
2004 (English)In: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 42, no 6, 770-6 p.Article in journal (Refereed) Published
Abstract [en]

Tissue motion of the beating heart generates large movement artifacts in the laser Doppler perfusion monitoring (LDPM) signal. The aim of the study was to use tissue Doppler imaging (TDI) to localise intervals during the cardiac cycle where the influence of movement artifacts on the LDPM signal is minimum. TDI velocities and LDPM signals were investigated on three calves, for normal heartbeat and during occlusion of the left anterior descending coronary artery. Intervals of low tissue velocity (TDIint, < 1 cm s(-1)) during the cardiac cycle were identified. During occlusion, these intervals were compared with low LDPM signal intervals (LDPMint, <50% compared with baseline). Low-velocity intervals were found in late systole (normal and occlusion) and late diastole (normal). Systolic intervals were longer and less sensitive to heart rate variation compared with diastolic ones. The overlap between LDPMint and TDIint in relation to TDIint length was 84+/-27% (n = 14). The LDPM signal was significantly (p < 0.001, n = 14) lower during occlusion if calculated during minimum tissue motion (inside TDIint), compared with averaging over the entire cardiac cycle without taking tissue motion into consideration. In conclusion, movement artifacts are reduced if the LDPM signal is correlated to the ECG and investigated during minimum wall motion. The optimum interval depends on the application; late systole and late diastole can be used.

Place, publisher, year, edition, pages
2004. Vol. 42, no 6, 770-6 p.
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-85847DOI: 10.1007/BF02345210ISI: 000225543500006PubMedID: 15587468OAI: oai:DiVA.org:kth-85847DiVA: diva2:500131
Note
QC 20120228Available from: 2012-02-13 Created: 2012-02-13 Last updated: 2017-12-07Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Janerot-Sjöberg, Birgitta

Search in DiVA

By author/editor
Janerot-Sjöberg, Birgitta
By organisation
Medical Engineering
In the same journal
Medical and Biological Engineering and Computing
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 41 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf