Change search
ReferencesLink to record
Permanent link

Direct link
Spherical aberration in contact lens wear
KTH, School of Engineering Sciences (SCI), Applied Physics, Biomedical and X-ray Physics.ORCID iD: 0000-0001-9172-858X
Show others and affiliations
2008 (English)In: Contact lens & anterior eye, ISSN 1367-0484, E-ISSN 1476-5411, Vol. 31, no 4, 189-193 p.Article in journal (Refereed) Published
Abstract [en]

Introduction: The aim of the present studies was to investigate the effect on spherical aberration of different non custom-made contact lenses, both with and without aberration control. Methods: A wavefront analyser (Zywave™, Bausch & Lomb) was used to measure the aberrations in each subject's right eye uncorrected and with the different contact lenses. The first study evaluated residual spherical aberration with a standard lens (Focus Dailies Disposable, Ciba Vision) and with an aberration controlled contact lens (ACCL) (Definition AC, Optical Connection Inc.). The second study evaluated the residual spherical aberrations with a monthly disposable silicone hydrogel lens with aberration reduction (PureVision, Bausch & Lomb). Results: Uncorrected spherical aberration was positive for all pupil sizes in both studies. In the first study, residual spherical aberration was close to zero with the standard lens for all pupil sizes whereas the ACCL over-corrected spherical aberration. The results of the second study showed that the monthly disposable lens also over-corrected the aberration making it negative. The changes in aberration were statistically significant (p < 0.05) with all lenses. Conclusion: Since the amount of aberration varies individually we suggest that aberrations should be measured with lenses on the eye if the aim is to change spherical aberration in a certain direction.

Place, publisher, year, edition, pages
2008. Vol. 31, no 4, 189-193 p.
Keyword [en]
Aberration control, Contact lenses, Daily disposable, Silicon hydrogel, Spherical aberration
National Category
URN: urn:nbn:se:kth:diva-87221DOI: 10.1016/j.clae.2008.05.005PubMedID: 18602857ScopusID: 2-s2.0-48949114935OAI: diva2:501532
QC 20120221Available from: 2012-02-14 Created: 2012-02-14 Last updated: 2012-02-21Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Unsbo, Peter
By organisation
Biomedical and X-ray Physics
In the same journal
Contact lens & anterior eye

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 65 hits
ReferencesLink to record
Permanent link

Direct link