Trådlösa sensorer för fuktindikering: Mosture indication with wireless sensors
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.
2012 (Swedish)Independent thesis Basic level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Användandet av trådlösa sensorer inom byggindustrin är relativt nytt. Sensible

solutions AB har utvecklat en produkt för fuktindikering som kan användas

i t.ex. lätta utfackningsväggar. Systemet bygger på att två stycken

passiva RFID-taggar fästs på ett kort med ett mellanrum så att inte taggarna

stör varandra. Den ena är täckt med en fuktabsorberande pappersbit som tar

upp fukt ur den omgivande luften medan den andra är öppen mot omgivande

luft. Sensorerna avläses med en RFID-läsare som sänder ut signaler tills

ett svar erhålls från båda taggarna. Den fuktiga taggen kommer att kräva en

större signalstyrka för att avläsas än den torra på grund av förändringar i dess

resonansfrekvens då taggen blivit fuktig. Då det krävs olika signalstyrkor för

att ladda upp vardera taggen kan differensen mellan de båda användas som

en fuktindikator. Sensorerna är relativt billiga och skulle kunna användas i

stora mängder för att tidigt upptäcka läckage, eller höga fuktnivåer.

Inom detta examensarbete har tester utförts för att avgöra hur tillförlitliga

sensorerna är med avseende på avstånd och riktningar till avläsningsenheten

samt inbördes avstånd mellan flera sensorer. Sensorerna har fått acklimatiseras

i behållare med olika saltlösningar som ger relativa fuktigheter mellan

12-97 %. De har sedan blivit avlästa för att avgöra hur värdena av differensen

i signalstyrka varierar med relativ fuktighet. Fördelar och begränsningar

med metoden har undersökts dels genom litteraturstudier och dels genom de

utförda testerna.

Testerna visar att metoden är känslig för avstånd och riktningar. Dock beror

troligtvis inte detta på sensorerna utan att den avläsningsenhet som används

i dagsläget har en del begränsningar. Metoden kräver att någon avläser de

manuellt på byggarbetsplatsen, t.ex. en platschef. I dagsläget finns endast en

gräns för att avgöra om det är torrt eller fuktigt. Gränsen är 5 dBm skillnad

mellan signalstyrkan för att ladda upp den fuktiga respektive den torra taggen.

Testerna som gjorts inom detta examensarbete har visat att fuktigare

luft innebär en större skillnad i signalstyrka mellan den öppna (referenstaggen)

och den inneslutna taggen. Vid avläsning krävs att avläsningsenheten

är riktad rakt mot kortet för att “korrekta” värden ska erhållas.

En ny, bättre avläsningsenhet kommer att börja användas under februari

2012. Därmed kommer en ny uppgradering av den kritiska fuktnivån.

ii

Abstract [sv]

The using of RFID-sensors in the Building industri is relatively new. Sensible

solutions AB have developed a product for moisture indication in for example

light weight exterior walls. The system is built upon one pair of passive RFIDtags

placed on a card with a space between them so that the tags don’t disturb

one another. One of the tags is covered with a moisture absorbing paper and

the other one is left open to the surrounding air. The sensors are read with an

RFID-reader which sends out signals until a response is received from both of

the tags. The moistened tag requires greater signal strength to be read than

the dry one because of changes in its resonance frequency when the tag is

covered in moisture. Since different signal strengths are required to read the

two tags, the difference between them can be used as a moisture indicator.

The sensors are relatively cheap and could therefore be used in great amount

to early discover leakage and high moisture levels.

Within this master thesis, tests have been made to evaluate how reliable the

sensors are in regard to distance between the reader and the sensors, the

angle between them and the distance between several different sensors. The

sensors have been acclimatized in exicators with different salt solutions which

are emitting relative humidity’s between 12-97 %. They have then been read

to determine how the values in the difference in signal strength varies with

relative humidity. The pros and cons with the method have been studied

through literature and the tests made.

The tests show that the method is sensitive to distances and angles. However

the limitation doesn’t depend on the sensors, but of the reader that is used

today. The method requires that someone is reading the sensors manually on

the construction site, for instance a construction site manager. Today there is

only one limit to determine if it’s dry or damp. The limit is 5 dBm differences

in power up level between the damp and the dry tag. The tests made in this

thesis shows that a higher moisture level leads to a greater difference in signal

strength between reading the open and the covered tag. When reading the

sensors it requires that the reader is aimed straight toward the sensor so that

“correct” values will be received.

A new, better reader will be used in February 2012. Consequently a new

upgrade of the critical moisture level will be made.

iii

Place, publisher, year, edition, pages
2012.
Series
Examensarbete Byggnadsteknik, 420
Keyword [sv]
fuktindikering trådlösa sensorer
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-93797OAI: oai:DiVA.org:kth-93797DiVA: diva2:523978
Subject / course
Building Technology
Educational program
Master of Science in Engineering - Urban Management
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-04-27 Created: 2012-04-27 Last updated: 2012-04-27Bibliographically approved

Open Access in DiVA

fulltext(12531 kB)291 downloads
File information
File name FULLTEXT01.pdfFile size 12531 kBChecksum SHA-512
8caca2be5319fd15f8125565e038b3b9faa81150e4568c2d08f648f5f07cd48760b22633ec20f1f9c253857dc8c32415292d0400f2aefc974cf84d9ed4250226
Type fulltextMimetype application/pdf
fulltext(12531 kB)458 downloads
File information
File name FULLTEXT02.pdfFile size 12531 kBChecksum SHA-512
8caca2be5319fd15f8125565e038b3b9faa81150e4568c2d08f648f5f07cd48760b22633ec20f1f9c253857dc8c32415292d0400f2aefc974cf84d9ed4250226
Type fulltextMimetype application/pdf

By organisation
Civil and Architectural Engineering
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 749 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1178 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf