Change search
ReferencesLink to record
Permanent link

Direct link
Automatic three-dimensional registration of intravascular optical coherence tomography images
KTH, School of Technology and Health (STH), Medical Engineering.ORCID iD: 0000-0002-5795-9867
Show others and affiliations
2012 (English)In: Journal of Biomedical Optics, ISSN 1083-3668, Vol. 17, no 2, 026005- p.Article in journal (Refereed) Published
Abstract [en]

Intravascular optical coherence tomography (IV-OCT) is a catheter-based high-resolution imaging technique able to visualize the inner wall of the coronary arteries and implanted devices in vivo with an axial resolution below 20 mu m. IV-OCT is being used in several clinical trials aiming to quantify the vessel response to stent implantation over time. However, stent analysis is currently performed manually and corresponding images taken at different time points are matched through a very labor-intensive and subjective procedure. We present an automated method for the spatial registration of IV-OCT datasets. Stent struts are segmented through consecutive images and three-dimensional models of the stents are created for both datasets to be registered. The two models are initially roughly registered through an automatic initialization procedure and an iterative closest point algorithm is subsequently applied for a more precise registration. To correct for nonuniform rotational distortions (NURDs) and other potential acquisition artifacts, the registration is consecutively refined on a local level. The algorithm was first validated by using an in vitro experimental setup based on a polyvinyl-alcohol gel tubular phantom. Subsequently, an in vivo validation was obtained by exploiting stable vessel landmarks. The mean registration error in vitro was quantified to be 0.14 mm in the longitudinal axis and 7.3-deg mean rotation error. In vivo validation resulted in 0.23 mm in the longitudinal axis and 10.1-deg rotation error. These results indicate that the proposed methodology can be used for automatic registration of in vivo IV-OCT datasets. Such a tool will be indispensable for larger studies on vessel healing pathophysiology and reaction to stent implantation. As such, it will be valuable in testing the performance of new generations of intracoronary devices and new therapeutic drugs.

Place, publisher, year, edition, pages
2012. Vol. 17, no 2, 026005- p.
Keyword [en]
optical coherence tomography, cardiovascular imaging, stent, image registration, rigid registration, image processing, segmentation, signal processing
National Category
Biochemistry and Molecular Biology
URN: urn:nbn:se:kth:diva-95127DOI: 10.1117/1.JBO.17.2.026005ISI: 000303033600021OAI: diva2:526771

QC 20120515. Crrection vol 17, 026005, 2012, DOI: 10.1117/1.JBO.17.4.049803, ISI:


Available from: 2012-05-15 Created: 2012-05-14 Last updated: 2013-04-24Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Larsson, Matilda
By organisation
Medical Engineering
In the same journal
Journal of Biomedical Optics
Biochemistry and Molecular Biology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 21 hits
ReferencesLink to record
Permanent link

Direct link