Optimization of experimental conditions of hot wire method in thermal conductivity measurements
KTH, School of Industrial Engineering and Management (ITM), Materials Science and Engineering. (Micro-modeling)
2012 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

This work studied the hot wire method in measuring thermal conductivity at room temperature. The purpose is to find the optimized experimental conditions to minimize natural convection in liquid for this method, which will be taken as reference for high temperature thermal conductivity measurement of slag. Combining room temperature experiments and simulation with COMSOL Multiphysics 4.2a, the study on different experimental parameters which may influence the accuracy of the measured thermal conductivity was conducted. The parameters studied were the diameter of crucible, the position of wire in the liquid, including z direction and x-y plane position, diameter of the hot wire, and current used in the measurement. In COMSOL simulations, the maximum natural convection velocity value was used to evaluate the natural convection in the liquid. The experiment results showed after 4~5 seconds of the measuring process, the natural convection already happened. Also when current was fixed, the thinner the hot wire, the larger convection it would cause. This is because thinner wire generates more heat per unit surface area. Using higher current in measuring, more heat generation improved accuracy of result but also had earlier and larger effect on convection. Both simulation and experiments showed that with the height of the liquid fixed, the smaller diameter of the crucible (not small to the level which is comparable with hot wire diameter), the higher the position in z direction (still covered by liquid), the less natural convection effect existed. But the difference was not significant. The radius-direction position change didn’t influence the result much as long as the wire was not too close to the wall.

Place, publisher, year, edition, pages
2012. , 30 p.
Keyword [en]
Thermal conductivity, hot wire method, simulation, conduction, convection, heat transfer
National Category
Other Materials Engineering
Identifiers
URN: urn:nbn:se:kth:diva-93765ISRN: KTH/MSE--12/06--SE+ MICROMODMETU/EXOAI: oai:DiVA.org:kth-93765DiVA: diva2:529074
Subject / course
Materials Science and Engineering
Educational program
Master of Science - Engineering Materials Science
Presentation
2012-03-22, Brinellvägen 23, Stockholm, 10:00 (English)
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-08-10 Created: 2012-04-26 Last updated: 2012-08-10Bibliographically approved

Open Access in DiVA

Master thesis work_Luyao Ma(1703 kB)1250 downloads
File information
File name FULLTEXT01.pdfFile size 1703 kBChecksum SHA-512
d682fe3ed5f845db5b6b1baf64a5d445cfcbc862d1bbd8b7c3bfdc0275b1af5d5655fb3f209c2f7d7151ea0a87f12786ecbe8d11742b17eed9d4c6d7304f3db2
Type fulltextMimetype application/pdf

By organisation
Materials Science and Engineering
Other Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1250 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 182 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf