Problem i högt fuktbelastade byggnader: Riskbedömning med hjälp av WUFI
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2012 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Problems in buildings with high moisture load : Risk assessment using WUFI (English)
Abstract [sv]

Många av Sveriges badhus byggda i slutet av 1900-talet börjar idag visa tecken på kraftiga fuktskador på grund av extrema inomhusklimat. Denna rapport förklarar den allmänna problematiken kring högt fuktbelastade byggnader och berör det fuktskadade badhuset Aquarena i Katrineholm.  Extrem noggrannhet krävs vid montering av ångspärr i en konstruktion, speciellt vid högt invändigt fukttillskott. Optimal placering av fuktspärren i konstruktionens varmare del innebär att fukt aldrig tillåts kondensera och därmed minimeras risken för fuktskador och negativa konsekvenser. Verkligheten visar också att om kunskaper om fukt och fuktskador prioriteras redan i ett tidigt stadium under projektering kan många hundratusentals kronor sparas. Beräkningar av fukttransport har gjorts för tidigare ytterväggskonstruktion i Aquarena (den som drabbats av skador) och nybyggd ytterväggskonstruktion (nyframtagen till återuppbyggnaden) i datorprogrammet WUFI Pro 4.2 och analyserats i WUFI Bio 3.0.  Beräkningarna visar att den tidigare väggkonstruktionen får de skador som undersökningar av den visat och att skadorna hade kunnat undgås om genomförningar i ångspärren hade utförts på ett korrekt sätt.  Vi har med beräkningar inte kunnat bevisa att alla delar i den nybyggda ytterväggskonstruktionen kommer fungera perfekt. Främst beror osäkerheten i beräkningar utförda i WUFI på att beräkningsmodellen inte är färdigutvecklad. Osäkerheter beror också på otillräcklig kännedom av egenskaper hos de simulerade materialen. Beräkningar för den nyframtagna väggkonstruktionen visar dock entydigt på bättre resultat än för den tidigare väggkonstruktionen. Det finns därför anledning att vidare utreda vilka värden på fukt och temperatur som kommer att råda över de närmaste åren. Detta bland annat för att senare kunna korrigera beräkningsmodellen efter verkligheten. 

Abstract [en]

Many of Sweden's public indoor swimming pools built in the late 1900’s are beginning to show signs of excessive moisture damage due to extreme indoor climate. This report explains the general problem of high moisture-loaded buildings and involves the moisture-damaged public indoor swimming pool Aquarena in Katrineholm. Extreme care is required when assembling the moisture barrier in a structure, especially with high internal moisture content. Optimal placement of the moisture barrier in the warmer parts of the construction means that moisture is never allowed to condense, thus minimizing the risk of moisture damage and negative consequences. Reality also shows that if risks of moisture and moisture damages are assessed early in the planning process, amounts in the range of hundreds of thousands of Swedish crowns can be saved. Calculations of moisture transport have been made for the previous exterior wall structure (the one that suffered damage) and new exterior wall structure the (new design for the reconstruction) using the computer program WUFI Pro 4.2 and analyzed in WUFI Bio 3.0. Calculations show that the old exterior wall structure in Aquarena would have been able to withstand moisture damage and damages due to moisture if joints and transitions in the moisture barrier had been correctly performed.  Calculations have not proven that all elements of the newly built wall design will work perfectly. The main reason for uncertainty in calculations when using WUFI is that the calculation model is not fully developed. Uncertainty is also due to insufficient knowledge of properties of the simulated materials. However, calculations show unambiguously better results than the previous wall construction. It is therefore necessary to further investigate what values of humidity and temperature will exist over the next few years to be able to later on correct the calculation model after reality. 

Place, publisher, year, edition, pages
2012. , 53 p.
Keyword [en]
Public indoor swimming pool, moisture, problems involving moisture, moisture damage, wall structure, mold, WUFI, WUFI Bio
Keyword [sv]
Badhus, simhall, fukt, fuktproblem, fuktskador, väggkonstruktion, mögel, WUFI, WUFI Bio
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-102110OAI: oai:DiVA.org:kth-102110DiVA: diva2:550933
External cooperation
WSP Environmental
Subject / course
Constructional Engineering and Design
Educational program
Bachelor of Science in Engineering - Constructional Engineering and Design
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-09-10 Created: 2012-09-09 Last updated: 2013-03-07Bibliographically approved

Open Access in DiVA

fulltext(2128 kB)909 downloads
File information
File name FULLTEXT01.pdfFile size 2128 kBChecksum SHA-512
06ee0110d13468a1e140997980dc0df61f420de77414559b10a4ecb8803b9c06880a4f027b21f6c8beca33f423105558f6c04815b0ed66ebf1aff9610a83027c
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 909 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 486 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf