Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Apparatur och metod för uppskattning av underkropsseffektutveckling
KTH, School of Industrial Engineering and Management (ITM), Machine Design (Dept.), Mechatronics.
2011 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Apparatus and Method for Lower Body Power Output Estimation (English)
Abstract [sv]

Sammanfattning

Riksidrottsförbundet har som stående mål att ständigt förbättra metoderna med vilka man testar

idrottare. Därför åtogs ett projekt med målet att undersöka vilken metod för att mäta

muskeleffektutveckling under fria skivstångsövningar som ska användas för att kunna ge

träningsråd. En sådan studie har tidigare gjorts av Cormie et al 2007 [9]. I denna studie

uppskattades muskeleffektutvecklingen med hjälp av vetskap om skivstångens position samt

idrottarens reaktionskrafter mot golvet.

Målet med den här rapporten var att utforma en testapparatur som kan upprepa de testmetoder

som är använda i Cormie et al 2007 [9], samt undersöka möjligheten till andra metoder för

uppskattning av muskeleffektutveckling och implementera dessa.

För att uppnå dessa mål genomfördes först en litteraturstudie där tidigare studier, teknik och

existerande system undersöktes. Sedan utvecklades modeller av mekaniken samt av själva

testuppställningen. Sist utformades själva apparaten bestående linjärpositionsgivare för

positionsbestämning av skivstången samt en kraftplatta för mätning av reaktionskrafterna. Data

samlades sedan in m.h.a. en PC och ett därför utvecklat gränssnitt gjort i LabVIEW, där

beräkningarna utförs. Som ett sista steg utfördes en begränsad försöksstudie för att kunna

jämföra med Cormie et al 2007 [9].

Den resulterande testapparaturen bestämmer positionen och orienteringen för stångens

masscentrum genom att mäta positionerna för två punkter på stången med totalt fem

linjärpositionsgivare. Reaktionskrafterna mäts m.h.a. en kraftplatta positionerad direkt under

utövaren. Allting i 3D.

I den här rapporten lägg även en ny metod för effektuppskattning fram. Den nya metoden

redogör för systemet atlet-skivstång som två kroppar som kan röra sig fritt oberoende av

varandra, där tidigare metoder enbart använt sig av en enkroppsmodell.

Försöksstudien uppvisade god överstämmelse med Cormie et al 2007 [9] vid jämföring av de

tidigare metoderna. Även den nyutvecklade metoden visade rimliga resultat i jämförelse med de

tidigare metoderna. Den nya metoden kan, i teorin, fånga mer av skivstångsrörelsernas natur.

Därför är rekommendationen i den här rapporten att denna metod i framtiden bör användas

Abstract [en]

Abstract

One of the Swedish sports federation RF’s ongoing goals is to find new and better methods of

testing athletes. Therefore a project, with the goal of investigating which method to use for

measuring lower body muscle power output during free barbell exercises, in order to give

training recommendations, was undertaken. This had already been done in a study done by

Cormie et al 2007 [9]. In this study, the muscle power output is estimated using methods relying

on knowledge of the position of the barbell and the athlete’s reaction forces acting on the floor.

The goals of this thesis was to make a test apparatus capable of repeating the test methods used

in Cormie et al 2007 [9], but also explore the possibility of finding other methods of muscle

power estimation and to implement these.

In order to reach these goals, first a literature study was carried out, looking at other previous

studies, technologies and commercial systems. Then models of the mechanics and the test setup

were developed. Lastly, the test apparatus was developed, using linear position transducers for

determining the position of the barbell, along with a force plate for measuring reaction forces.

The data was then collected and analyzed using a PC-system developed in LabVIEW. As a final

step, a limited trial was conducted in order to compare results with Cormie et al 2007 [9].

The resulting apparatus determines the position of the barbell’s center of mass and its orientation

in space, measuring the position of two points on the barbell using a total of five linear position

transducers, three on one side and two on the other. The reaction forces are measured using a

force plate position under the athlete. All of this, in 3D.

One new method of estimating muscle power output is also presented in this thesis. This method

accounts for the lifter and the barbell as two separate bodies, able to move independently,

whereas the previous method of choice only accounts for them as one stiff body.

The trial showed good coherence with Cormie et al 2007 [9], comparing the same methods. Also

the new method gave results that seem reasonable in comparison with the old methods’ results.

The conclusion and recommendation of this report is to, in the future, use this new method. This

new method should, in theory, be able to capture more of the reality of free barbell exercises than

the old method. The conclusion of this report is therefore that this method should be used.

Place, publisher, year, edition, pages
2011. , 58 p.
Series
MMK 2011:56 MDA 413
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-103809OAI: oai:DiVA.org:kth-103809DiVA: diva2:561901
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-10-22 Created: 2012-10-22 Last updated: 2012-10-22Bibliographically approved

Open Access in DiVA

Apparatus and Method for Lower Body(7891 kB)223 downloads
File information
File name FULLTEXT01.pdfFile size 7891 kBChecksum SHA-512
a10148feaf0c1219499a69e5b1c0b69f09a9ce345cbfc24b0321e5b67a61264a92affc90a00208d36b486a542fd5aa09c9ae9c481c800c06eb6e0e5965f12ddb
Type fulltextMimetype application/pdf

By organisation
Mechatronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 223 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 295 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf