Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Dynamic analysis of the impact of grid connection of "La Higuera" hydropower plant to the transmission grid
KTH, School of Electrical Engineering (EES), Electric Power Systems.
2006 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Studies regarding the development of a new hydropower plant exploiting the water resources offered by the upper Tinguiririca river, located about 150 km south-east of the capital Santiago in Chile, has been done by Pacific Hydro Ltd from Australia and Lahmeyer International from Germany. These studies have resulted in proposals to construct two Hydropower Stations, �La Higuera� and �Confluencia�. Both hydropower stations will have a total installed capacity of 300 MW.

When setting up a new hydropower plant, it is important to foresee how the hydropower plant would affect the existing transmission grid in different situations during operation as well as how events in the grid may affect the La Higuera and/or Confluencia hydropower stations. In this report three kind of analysis are highlighted, which are static analysis, large signal stability and rotor angle stability. To perform these analyses a simulation tool named DigSilent is used. DigSilent is used to perform these analyses in a simulated network of the studied transmission system.

These two hydropower stations as shown in the results will improve the existing transmission system by enhancing the stability margins in the presence of a fault. When performing the simulation of the existing transmission system with the newly installed hydropower plant we could see that it had a poor damping after a disturbance; this might be due to the large distance between production plants and the existing loads. This phenomenon can be alleviated if a power system stabilizer (PSS) is integrated in the hydropower plant.

The final conclusion is that the integration of the two hydropower plants will improve the existing transmission system in Chile.

Place, publisher, year, edition, pages
2006. , 55 p.
Series
EES Examensarbete / Master Thesis
Keyword [en]
Electric Power System, Load flow, Voltage Stability, Hydropower, DigSilent
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-118929OAI: oai:DiVA.org:kth-118929DiVA: diva2:609101
Educational program
Master of Science - Electric Power Engineering
Uppsok
Technology
Examiners
Available from: 2013-03-12 Created: 2013-03-04 Last updated: 2013-03-12Bibliographically approved

Open Access in DiVA

fulltext(1171 kB)269 downloads
File information
File name FULLTEXT01.pdfFile size 1171 kBChecksum SHA-512
07cbcacdec5412ad7e0a6cbe6723e927e2b979f353ec9db797834179eb13d74a91a7b6993247f510692bd451afb24ffb3c3ab1d5959c454fff419117418b1db2
Type fulltextMimetype application/pdf

By organisation
Electric Power Systems
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 269 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 175 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf