Dynamisk tredimensionell visualisering av fot med datortomografi
KTH, School of Technology and Health (STH).
KTH, School of Technology and Health (STH).
2013 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Dynamic three-dimensional visualization of the foot using computed tomography (English)
Abstract [sv]

Projektets syfte var att med modern datortomografi (computed tomography, CT) skapa tidsupplösta tredimensionella sekvenser, även kallade 4D-sekvenser, med låg stråldos och tillräckligt bra upplösning samt att påbörja en implementering av denna metod på Karolinska Universitetssjukhuset i Huddinge. För att få ett så bra resultat som möjligt involverades ett antal personer med olika medicinsk yrkesbakgrund och olika kompetensområden.

En fantomstudie utfördes genom att dra ett fantom med en konstant hastighet genom CT:n med hjälp av en motor. Efter detta utfördes en pilotstudie på två försökspersoners högerfötter som utförde en rörelse under olika lång tid under en CT-undersökning.

Scanningen av fötterna genomfördes först efter att det visade sig att scanningen av fantomet gav adekvat resultat med avseende på bildkvalitet och stråldos. För att avgöra detta gjordes en analys av bilderna på fantomet och en dosberäkning.

Scanningen av fötterna genererade tolkningsbara bilder med tillräckligt låg stråldos. Denna metod kommer därför säkerligen användas i undervisnings- och forskningssyfte. Den kan även användas kliniskt på Karolinska Universitetssjukhuset i Huddinge i framtiden, till exempel vid diagnostisering och rehabilitering av senor.

Abstract [en]

The purpose of the project was to create time-resolved three-dimensional sequences, so called 4D sequences, using computed tomography (CT) with low radiation dose and sufficient resolution and to start an implementation of this method at Karolinska University Hospital in Huddinge. To get as good result as possible a number of people with different medical professional background was involved.

A phantom study was performed by moving a phantom with a constant velocity through the CT using a motor. After this, a pilot study was performed by scanning the right foot of two people who performed a movement for various lengths of time during a CT-scan.

The scanning of the feet was done after the phantom gave adequate result with respect to image quality and radiation dose. To determine this, analyze of the images of the phantom and a calculation of the dose was made.

The scanning of the feet generated interpretable images with sufficiently low radiation dose. This method will certainly be used in teaching and research purposes. It can also be used clinically at Karolinska University Hospital in Huddinge in the future, for example for the diagnosis and rehabilitation of tendons.

Place, publisher, year, edition, pages
2013. , 48 p.
Series
Trita-STH, 2013:69
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-124560OAI: oai:DiVA.org:kth-124560DiVA: diva2:638191
External cooperation
Karolinska Institutet; Institutionen för klinisk vetenskap, interventioner och teknik, CLINTEC och Karolinska Universitetssjukhuset i Huddinge
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
Supervisors
Examiners
Available from: 2013-08-04 Created: 2013-07-11 Last updated: 2013-08-04Bibliographically approved

Open Access in DiVA

ANGELICA_CECILIA_KEX(980 kB)669 downloads
File information
File name FULLTEXT02.pdfFile size 980 kBChecksum SHA-512
48e283ed42003017a2d64deae51c6d27f173bbce7d092b9248589e1d5c504401fc3a1415a9e541505c168f2fd201caba0b3d93f322cad85507d6c7f0d127a5c1
Type fulltextMimetype application/pdf
FILM_FÖTTER(602 kB)69 downloads
File information
File name MOVIE02.flvFile size 602 kBChecksum SHA-512
55d5db0cf0a7322405a0c01b3974c46da9b7e0a29429a80aab93062d2065515bc95c8e45335f6302a024de081662a8b475dfff469dcd3a7ac7225dba70048dd8
Type movieMimetype video/x-flv

By organisation
School of Technology and Health (STH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 669 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 196 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf