Prototype Development of an A-Mode Ultrasound Based Intrafraction Motion Management System
KTH, School of Technology and Health (STH).
KTH, School of Technology and Health (STH).
2013 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Owing to the steep dose fall-off curves of high precision and accuracy radiation therapy (RT) modalities such as stereotactic body RT (SBRT), treatment plans with extraordinarily small margins to organs at risk (OARs), such as the spinal cord, has been made possible. With this development, patient movements during treatment, i.e. intrafraction motion (IFM), must be monitored more closely. This master thesis was aimed at developing an A-mode ultrasound prototype to detect the motions of the cervical spine as part of an IFM management (IFMM) system. Current IFMM systems have several drawbacks, including invasiveness and indirect measurements.

The existing prototype was tested in order to identify areas of improvement. The prototype developed was equipped with a preconditioning circuit that retains the frequency information of the signal. Furthermore, software was developed based on wavelet filtering and enveloping using the Hilbert transform. Multiple logic algorithms were added in order to handle lost signals, competing echoes, echoes from soft tissues etc.

The newly-developed prototype was found to have higher accuracy and precision than the pre-existing prototype. It was also more robust when measuring distance to the spine. A difficulty in segmenting the echo for bone arises for low quality signals. Therefore a compromise exists between setup time, including probe adjustment, and signal quality. Future work includes the manufacturing of a new neck rest to enable robust probe adjustment and fixation.

Place, publisher, year, edition, pages
2013. , 90 p.
Series
Trita-STH, 2013:94
Series
Ph
Keyword [en]
Intrafraction motion management, A-mode ultrasound, stereotactic body radiation therapy, ultrasonic distance measurement, embedded system
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-126019OAI: oai:DiVA.org:kth-126019DiVA: diva2:641585
External cooperation
ELEKTA INSTRUMENT AB
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
Supervisors
Examiners
Available from: 2013-08-23 Created: 2013-08-18 Last updated: 2013-08-23Bibliographically approved

Open Access in DiVA

HAILU_LUNDQVIST_STUDENT_THESIS(2912 kB)1176 downloads
File information
File name FULLTEXT01.pdfFile size 2912 kBChecksum SHA-512
cd47171e6c075685f179835c766d54e6b6e27fc57d6cd07944675c54bad8c8a40c4d63c9926e5562078e045f3d889902068f213d2b406311d68d27323ff96da8
Type fulltextMimetype application/pdf

By organisation
School of Technology and Health (STH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1176 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 357 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf