Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Analys av lokala otätheters påverkan i ytterväggskonstruktioner: Analys och riskbedömning med programmen WUFI and WUFI-Bio
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2013 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Analysis of local leakages' effect in exterior wall constructions : Analysis and assessment with the programs WUFI and WUFI-Bio (English)
Abstract [sv]

Många byggnader är idag fuktskadade. Fuktskador uppstår på så väl nya som gamla byggnader. Idag provtrycker man hus för att få ett värde på dess täthet, men många hus som klarar täthetskraven drabbas ändå av fuktskador. Detta beror på att otätheterna är lokala på en eller flera delar av klimatskalet bortsett från otätheter vid anslutningar.  

En studie har gjorts på två väggtyper; en standardvägg och en passivhusvägg. Denna undersökning har begränsats till väggar för småhus. Undersökningen syftar till att ta fram vart gränserna går innan mögeltillväxt påvisas för olika håldiametrar i plastfolien. Jämförelse gjordes för dessa väggkonstruktioner i städerna Kiruna, Stockholm och Lund.

Simulering av konstruktionerna i de olika städerna gjordes i programmet WUFI Pro 5,0 med en 5-årsperiod där resultaten sedan analyserats i WUFI-Bio 3,1 RC för riskbedömning av mikrobiell tillväxt.

Resultat åskådliggör att konstruktioner med tjockare isolering belägna längre upp i landet lättare kan råka ut för skador orsakade av fukt.

Abstract [en]

Many buildings today are moisture damaged. Moisture damage occurs to new as well as old buildings. Nowadays we test the dense of the building with measurement of the air flow under pressure, but still many of these building structures that meet the dense requirements are still affected by dampness. This is because the leaking points are situated at one or other parts of the building shell other than at the connections.A study has been made on two wall types: a standard wall and a passive house wall. This investigation has been confined to walls of houses. The study aims to develop each boundaries before mold growth demonstrated for different hole diameters in plastic foil. Comparison was made for these wall structures in the cities Kiruna, Stockholm and Lund.The comparison of the wall structures in the different towns was done with a simulation program WUFI Pro 5.0 for a 5-year period. Results were then analyzed in WUFI Bio 3.1 RC, program for risk assessment of microbial growth.Results illustrate that structures with thicker insulation located further up in the country can more easily encounter damage caused by moisture.

Place, publisher, year, edition, pages
2013. , 54 p.
Keyword [en]
moisture damage, pressure test, density requirements, local leaks, building shell, wall constructions, houses, microbial growth, WUFI Pro 5, 0, WUFI-Bio 3, 1 RC
Keyword [sv]
fuktskador, provtryckning, täthetskrav, lokala otätheter, klimatskal, väggkonstruktioner, småhus, mikrobiell tillväxt, WUFI Pro 5, 0, WUFI-Bio 3, 1 RC
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-127420OAI: oai:DiVA.org:kth-127420DiVA: diva2:644147
External cooperation
AK-konsult Indoor Air AB
Educational program
Bachelor of Science in Engineering - Constructional Engineering and Design
Uppsok
Technology
Supervisors
Examiners
Available from: 2013-08-29 Created: 2013-08-29 Last updated: 2013-08-29Bibliographically approved

Open Access in DiVA

fulltext(2689 kB)431 downloads
File information
File name FULLTEXT01.pdfFile size 2689 kBChecksum SHA-512
b87cf3c26b3843e6e2e38de23d25b944337c2d11493c4540142c5de6dca356279dc719b21d0e518d0acf18138614fcfe032a12c6bd9e4dc9fbcad41757fe34e5
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 431 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 473 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf