Abstract [en]

A study to optimize insulation thickness for stock-, industrial- and office-buildings for external walls and roof in an economical perspective has been conducted on behalf of DynaMate. DynaMate’s role is to maintain all Scania’s buildings. Analysis has also included other parts of the building envelope, such as windows, exterior doors and industrial doors. In this thesis, three different types of exterior wall constructions has been investigated, these are a sandwich design consisting of sheet metal and a another one consisting of concrete, as well as a wall of concrete with a coating of plasters. Furthermore, two types of roof structures have been studied, these are TRP-sheets and a concrete structure, both of which are externally isolated. For all types of building envelopes, different standard thicknesses of insulation have been used and the U-value of the windows has been varied.

To calculate the energy needed for the different kinds of buildings, the program IDA Indoor Climate and Energy has been used.  Furthermore, a sensitivity analysis of the air tightness has been implemented for the building envelope. Based on the program results LCC (Life-cycle cost) calculations have been carried out for all combinations, thus be able to form an idea of ​​the combination and what kind of structure that is most economically tenable.

A thermograph study was conducted in an existing warehouse at Scania. Observations show that the connection between the sandwich material of sheet metal and the foundation wall is flawed as this has a much lower thermal resistance compared to other parts of the building envelope. An alternative connection was developed which reduces the heat loss to one-fifth of the initial connection.

An analysis regarding the companies approach to the vapour barrier in roof structures for industrial buildings has been investigated from a moisture standpoint. The analysis shows that without a functioning vapour barrier the moisture content in the construction increases over time, which leads to increased heating costs.

The conclusion of this study shows that a reduction of insulation thickness for all types of studied buildings is more economically tenable than increasing the thickness. This is mainly due to the high cost of capital that the company uses for these investments. This means that any savings on cooling and heating costs very quickly is overthrown by the interest rate of the additional cost of the investment.

Place, publisher, year, edition, pages
2013. , 184 p.
, TRITA-BKN. Master Thesis 431, 2013
Keyword [en]
building envelope, energy consumption, LCC, office, warehouses, industrial buildings
National Category
Engineering and Technology Civil Engineering
URN: urn:nbn:se:kth:diva-129517OAI: diva2:652595
Subject / course
Building Technology
Educational program
Master of Science in Engineering - Urban Management
Available from: 2013-10-01 Created: 2013-10-01 Last updated: 2013-10-01Bibliographically approved

Open Access in DiVA

fulltext(7534 kB)506 downloads
File information
File name FULLTEXT01.pdfFile size 7534 kBChecksum SHA-512
Type fulltextMimetype application/pdf

By organisation
Building Technology
Engineering and TechnologyCivil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 506 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 478 hits
ReferencesLink to record
Permanent link

Direct link