A novel method to generete synthetic ultrasound data of the carotid artery based on in vivo observation as a tool to validate algorithm accuracy
KTH, School of Technology and Health (STH), Medical Engineering.ORCID iD: 0000-0002-5795-9867
Show others and affiliations
2012 (English)In: 2012 IEEE International Ultrasonics Symposium (IUS), 2012, 1674-1677 p.Conference paper, Published paper (Refereed)
Abstract [en]

Ultrasound imaging represents a well designed modality to estimate the motion of biological tissues in vivo, from which relevant clinical information can be assessed. However, the lack of ground truth constitutes a challenging issue when it comes to evaluate the accuracy of computerized methods. Indeed, quantification of the reliability of experimental results often involves manual or visual human operations, which may introduce subjectivity and variability. Nonetheless, numerical simulation of the imaged tissues allow a comparison with a known reference. For this purpose, we propose in this work a realistic kinematic multi-layer model of the common carotid artery. A set of 10 models was generated by randomly positioning scatterers, on which intensity, specular reflection, and bi-dimensional motion over the duration of one cardiac cycle were applied. Two computerized methods, namely a block-matching method and a segmentation method, were also applied on our model using identical parameter settings as those used for in vivo clinical data, in the objective to assess their accuracy. The tracking errors were 42 ± 40 μm and 12 ± 10 μm in the longitudinal and radial directions, respectively. The segmentation errors were 28±18 μm for the lumen diameter, and 15±10 μm for the intima-media thickness. We conclude from these results that our model can constitute a reliable method to quantify the accuracy of computerized algorithms.

Place, publisher, year, edition, pages
2012. 1674-1677 p.
Series
IEEE International Ultrasonics Symposium, IUS, ISSN 1948-5719
Keyword [en]
Algorithm accuracies, Clinical information, Common carotid artery, Computerized methods, Intima-media thickness, Segmentation error, Segmentation methods, Specular reflections, Errors, Ultrasonic imaging, Algorithms
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:kth:diva-131325DOI: 10.1109/ULTSYM.2012.0420ISI: 000326960201107Scopus ID: 2-s2.0-84882324392OAI: oai:DiVA.org:kth-131325DiVA: diva2:656021
Conference
2012 IEEE International Ultrasonics Symposium, IUS 2012; Dresden; Germany; 7 October 2012 through 10 October 2012
Note

QC 20131014

Available from: 2013-10-14 Created: 2013-10-14 Last updated: 2017-09-28Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Authority records BETA

Larsson, Matilda

Search in DiVA

By author/editor
Larsson, Matilda
By organisation
Medical Engineering
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 35 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf