Oil Aging due to Partial Discharge Activity
KTH, School of Electrical Engineering (EES), Electromagnetic Engineering. (High voltage group)ORCID iD: 0000-0003-1766-8077
KTH, School of Electrical Engineering (EES), Electromagnetic Engineering. (High voltage group)
KTH, School of Electrical Engineering (EES), Electromagnetic Engineering. (High voltage group)
2013 (English)In: Proceedings of the23rd NORDIC INSULATIONSYMPOSIUM, NORD-IS &Akademika Publishing , 2013, 85-88 p.Conference paper, Published paper (Other (popular science, discussion, etc.))
Abstract [en]

Oil is the main insulation in power transformers and over long time of ageing its insulation properties can change. In this paper ageing of oil due to the exposure to electric discharges was investigated. The effect of high energy discharges (complete arc) and low energy discharges (partial discharges) on oil properties such as breakdown strength and oil conductivity was investigated. An experimental setup consisting of two spherical electrodes was designed. The adjustable distance between the two electrodes made it possible to have PD with different magnitude. The oil conductivity and breakdown strength was measured for three sets of experiments. The first group of experiments was performed on new oil in order to have a reference for comparison. In the second group of experiments the new oil samples was exposed to 1000 and 3000 lightning impulses. In the third group of experiments new oil samples was exposed to partial discharge for different duration of time. Oil conductivity and breakdown strength of these aged samples were compared with new oil. The results show that after exposure to lightning impulse oil conductivity increases and breakdown strength decreases, However PD activity for short time does not change the oil conductivity but it reduces the breakdown strength.

Place, publisher, year, edition, pages
NORD-IS &Akademika Publishing , 2013. 85-88 p.
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-137983ISBN: 978-82-321-0274-7 (print)OAI: oai:DiVA.org:kth-137983DiVA: diva2:680051
Conference
23rd NORDIC INSULATION SYMPOSIUM,NORDI-IS13 June 9–12, 2013 Trondheim, Norway
Note

QC 20140107

Available from: 2013-12-17 Created: 2013-12-17 Last updated: 2015-02-06Bibliographically approved

Open Access in DiVA

Nordis2013(753 kB)269 downloads
File information
File name FULLTEXT01.pdfFile size 753 kBChecksum SHA-512
c49abf8db96df7896764f05125d0aa4a73bfac9461d097031e6595d4b16376b4d25b4d974935d4d5f6e61dd5b7824796408416e3278752e02cf1bda6f5ab4276
Type fulltextMimetype application/pdf

Other links

NORD-IS 2013

Authority records BETA

Ghaffarian Niasar, Mohamad

Search in DiVA

By author/editor
Ghaffarian Niasar, MohamadEdin, HansKiiza, Respicus
By organisation
Electromagnetic Engineering
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 269 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 93 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf