Experiments using a 10 MW Kaplan hydropower machine with a PowerFormerTM generator (the Porjus U9 research machine) are described. This machine has an extensive array of sensors to determine oil film thickness, pad tilting, pad load and oil temperature in all three guide bearings, as well as motion of the shaft in relation to both the bearing housings and the concrete foundation. Test results for all three guide bearings are examined during both steady-state and transient operation.

Place, publisher, year, edition, pages
2013. Vol. 20, no 5, 94-100 p.
Keyword [en]
Array of sensors, Bearing housing, Concrete foundation, Guide bearing, Oil film thickness, Oil temperature, Operational transients, Transient operation, Energy resources, Hydroelectric power, Hydraulic structures
National Category
Mechanical Engineering
URN: urn:nbn:se:kth:diva-139967ScopusID: 2-s2.0-84887010745OAI: diva2:689761

QC 20140121

Available from: 2014-01-21 Created: 2014-01-16 Last updated: 2014-06-11Bibliographically approved

Open Access in DiVA

No full text


Search in DiVA

By author/editor
Glavatskih, Sergei
By organisation
Machine Design (Dept.)
In the same journal
International journal on hydropower and dams
Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 63 hits
ReferencesLink to record
Permanent link

Direct link