Change search
ReferencesLink to record
Permanent link

Direct link
A novel strategy to translate the biomechanical rupture risk of abdominal aortic aneurysms to their equivalent diameter risk: Method and retrospective validation
KTH, School of Engineering Sciences (SCI), Solid Mechanics (Dept.).
Show others and affiliations
2014 (English)In: European Journal of Vascular and Endovascular Surgery, ISSN 1078-5884, E-ISSN 1532-2165, Vol. 47, no 3, 288-295 p.Article in journal (Refereed) Published
Abstract [en]

Objective: To translate the individual abdominal aortic aneurysm (AAA) patient's biomechanical rupture risk profile to risk-equivalent diameters, and to retrospectively test their predictability in ruptured and non-ruptured aneurysms. Methods: Biomechanical parameters of ruptured and non-ruptured AAAs were retrospectively evaluated in a multicenter study. General patient data and high resolution computer tomography angiography (CTA) images from 203 non-ruptured and 40 ruptured aneurysmal infrarenal aortas. Three-dimensional AAA geometries were semi-automatically derived from CTA images. Finite element (FE) models were used to predict peak wall stress (PWS) and peak wall rupture index (PWRI) according to the individual anatomy, gender, blood pressure, intraluminal thrombus (ILT) morphology, and relative aneurysm expansion. Average PWS diameter and PWRI diameter responses were evaluated, which allowed for the PWS equivalent and PWRI equivalent diameters for any individual aneurysm to be defined. Results: PWS increased linearly and PWRI exponentially with respect to maximum AAA diameter. A size-adjusted analysis showed that PWS equivalent and PWRI equivalent diameters were increased by 7.5 mm (p = .013) and 14.0 mm (p < .001) in ruptured cases when compared to non-ruptured controls, respectively. In non-ruptured cases the PWRI equivalent diameters were increased by 13.2 mm (p < .001) in females when compared with males. Conclusions: Biomechanical parameters like PWS and PWRI allow for a highly individualized analysis by integrating factors that influence the risk of AAA rupture like geometry (degree of asymmetry, ILT morphology, etc.) and patient characteristics (gender, family history, blood pressure, etc.). PWRI and the reported annual risk of rupture increase similarly with the diameter. PWRI equivalent diameter expresses the PWRI through the diameter of the average AAA that has the same PWRI, i.e. is at the same biomechanical risk of rupture. Consequently, PWRI equivalent diameter facilitates a straightforward interpretation of biomechanical analysis and connects to diameter-based guidelines for AAA repair indication. PWRI equivalent diameter reflects an additional diagnostic parameter that may provide more accurate clinical data for AAA repair indication.

Place, publisher, year, edition, pages
2014. Vol. 47, no 3, 288-295 p.
Keyword [en]
Aneurysm repair indication, Aneurysms rupture, Biomechanical analysis, Computer-based model, Risk assessment
National Category
Medical and Health Sciences
URN: urn:nbn:se:kth:diva-142343DOI: 10.1016/j.ejvs.2013.12.018ISI: 000332265500012ScopusID: 2-s2.0-84893855919OAI: diva2:699694
Swedish Foundation for Strategic Research Swedish Research CouncilVinnovaEU, FP7, Seventh Framework Programme, FAD-200647

QC 20140228

Available from: 2014-02-28 Created: 2014-02-28 Last updated: 2014-04-07Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Gasser, T. Christian
By organisation
Solid Mechanics (Dept.)
In the same journal
European Journal of Vascular and Endovascular Surgery
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 44 hits
ReferencesLink to record
Permanent link

Direct link