Static Integral Nonlinearity Modeling and Calibration of Measured and Synthetic Pipeline Analog-to-Digital Converters
KTH, School of Electrical Engineering (EES), Signal Processing.
KTH, School of Electrical Engineering (EES), Signal Processing.ORCID iD: 0000-0002-2718-0262
Show others and affiliations
2014 (English)In: IEEE Transactions on Instrumentation and Measurement, ISSN 0018-9456, E-ISSN 1557-9662, Vol. 63, no 3, 502-511 p.Article in journal (Refereed) Published
Abstract [en]

The integral nonlinearity (INL) modeling of pipeline analog-to-digital converters (ADCs) is investigated in this paper. The INL is divided into two distinct entities: a low code frequency (LCF) component and a high code frequency (HCF) component. Two static models are developed to represent the INL data. In both models, the LCF component is represented by a low-order polynomial. The HCF modeling is performed using two different basis functions: sinc and Gaussian. The structure of both HCF models is motivated by the pipeline architecture of the ADC under investigation. The model coefficients are estimated by applying the least-squares method to the measured INL data from two samples of a commercial pipeline ADC. The estimated HCF models are compared to each other and to previous models presented in the existing literature. In addition, the modeling methods are applied to synthetic HCF data generated by a pipeline ADC simulation model constructed in MATLAB. The INL models are then used to calibrate the synthetic ADCs, and the improvements in spurious free dynamic range are compared to those obtained when the ADCs are compensated by the INL data. Furthermore, the capability of the HCF modeling to calibrate a given ADC is tested by using the HCF model to compensate a synthetically generated ADC output in which only the measured HCF sequence and noise are added to the quantization process. The results show that the developed HCF models can achieve virtually complete calibration of the considered ADC.

Place, publisher, year, edition, pages
2014. Vol. 63, no 3, 502-511 p.
Keyword [en]
Integral nonlinearity (INL), modeling, Monte Carlo simulations, pipeline analog-to-digital converter (ADC), static calibration, synthetic data
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-143429DOI: 10.1109/TIM.2013.2282002ISI: 000331445400001Scopus ID: 2-s2.0-84894532758OAI: oai:DiVA.org:kth-143429DiVA: diva2:706738
Note

QC 20140321

Available from: 2014-03-21 Created: 2014-03-21 Last updated: 2017-12-05Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Authority records BETA

Händel, PeterJansson, Magnus

Search in DiVA

By author/editor
Medawar, SamerHändel, PeterJansson, Magnus
By organisation
Signal Processing
In the same journal
IEEE Transactions on Instrumentation and Measurement
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 85 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf