Change search
ReferencesLink to record
Permanent link

Direct link
Theoretical Comparison of the Iodine Quantification Accuracy of Two Spectral CT Technologies
KTH, School of Engineering Sciences (SCI), Physics, Physics of Medical Imaging.
KTH, School of Engineering Sciences (SCI), Physics, Physics of Medical Imaging.ORCID iD: 0000-0002-5092-8822
2014 (English)In: IEEE Transactions on Medical Imaging, ISSN 0278-0062, E-ISSN 1558-254X, Vol. 33, no 2, 556-565 p.Article in journal (Refereed) Published
Abstract [en]

We compare the theoretical limits of iodine quantification for the photon counting multibin and dual energy technologies. Dual energy systems by necessity have to make prior assumptions in order to quantify iodine. We explicitly allow the multibin system to make the same assumptions and also allow them to be wrong. We isolate the effect of technology from imperfections and implementation issues by assuming both technologies to be ideal, i.e., without scattered radiation, unity detection efficiency and perfect energy response functions, and by applying the Cramer-Rao lower bound methodology to assess the quantification accuracy. When priors are wrong the maximum likelihood estimates will be biased and the mean square error of the quantification error is a more appropriate figure of merit. The evaluation assumes identical X-ray spectra for both methodologies and for that reason a sensitivity analysis is performed with regard to the assumed X-ray spectrum. We show that when iodine is quantified over regions of interest larger than 6 cm, multibin systems benefit by independent estimation of three basis functions. For smaller regions of interest multibin systems can increase quantification accuracy by making the same prior assumptions as dual energy systems.

Place, publisher, year, edition, pages
2014. Vol. 33, no 2, 556-565 p.
Keyword [en]
Dual energy computed tomography (CT), iodine quantification, photon counting multibin CT, spectral CT
National Category
Radiology, Nuclear Medicine and Medical Imaging
URN: urn:nbn:se:kth:diva-143448DOI: 10.1109/TMI.2013.2290198ISI: 000331298000027ScopusID: 2-s2.0-84894053605OAI: diva2:707475

QC 20140324

Available from: 2014-03-24 Created: 2014-03-21 Last updated: 2014-03-24Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Bornefalk, HansPersson, Mats
By organisation
Physics of Medical Imaging
In the same journal
IEEE Transactions on Medical Imaging
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score