Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Model-based control strategy for 6-DOF haptic devices
KTH, School of Industrial Engineering and Management (ITM), Machine Design (Dept.), Machine Design (Div.). (Haptic Group)
KTH, School of Industrial Engineering and Management (ITM), Machine Design (Dept.), Machine Design (Div.). (System and Component Design)ORCID iD: 0000-0001-6692-2794
KTH, School of Industrial Engineering and Management (ITM), Machine Design (Dept.). (System and Component Design)
(English)Manuscript (preprint) (Other academic)
National Category
Other Mechanical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-144215OAI: oai:DiVA.org:kth-144215DiVA: diva2:712428
Note

QS 2014

Available from: 2014-04-15 Created: 2014-04-15 Last updated: 2014-04-15Bibliographically approved
In thesis
1. Effective development of haptic devices using a model-based and simulation-driven design approach
Open this publication in new window or tab >>Effective development of haptic devices using a model-based and simulation-driven design approach
2014 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Virtual reality (VR)-based surgical simulators using haptic devices can increase the effectiveness of surgical training for surgeons when performing surgical procedures in hard tissues such as bones or teeth milling. The realism of virtual surgery through a surgical simulator depends largely on the precision and reliability of the haptic device, which reflects the interaction with the virtual model. The quality of perceptiveness (sensation, force/torque) depends on the design of the haptic device, which presents a complex design space due to its multi-criteria and conflicting character of functional and performance requirements. These requirements include high stiffness, large workspace, high manipulability, small inertia, low friction, high transparency, and cost constraints.

This thesis proposes a design methodology to improve the realism of force/torque feedback from the VR-based surgical simulator while fulfilling end-user requirements.

The main contributions of this thesis are:

1. The development of a model-based and simulation-driven design methodology, where one starts from an abstract, top-level model that is extended via stepwise refinements and design space exploration into a detailed and integrated systems model that can be physically realized.

2. A methodology for creating an analytical and compact model of the quasi-static stiffness of a haptic device, which considers the stiffness of actuation systems, flexible links and passive joints.

3. A robust design optimization approach to find the optimal numerical values for a set of design parameters to maximize the kinematic, dynamic and kinetostatic performances of a 6-degrees of freedom (DOF) haptic device, while minimizing its sensitivity to variations in manufacturing tolerances and cost, and also satisfying the allowed variations in the performance indices.

4. A cost-effective approach for force/torque feedback control using force/torque estimated through a recursive least squares estimation.

5. A model-based control strategy to increase transparency and fidelity of force/torque feedback from the device by compensating for the natural dynamics of the device, friction in joints, gravity of platform, and elastic deformations.

 

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2014. xiii, 55 p.
Series
TRITA-MMK, ISSN 1400-1179 ; 2014:02
Keyword
Haptic device, model-based design, design optimization
National Category
Other Mechanical Engineering
Identifiers
urn:nbn:se:kth:diva-144216 (URN)978-91-7595-063-1 (ISBN)
Public defence
2014-04-23, F3, Lindstedtsvägen 26, KTH, Stockholm, 10:00 (English)
Opponent
Supervisors
Note

QC 20140415

Available from: 2014-04-15 Created: 2014-04-15 Last updated: 2014-04-15Bibliographically approved

Open Access in DiVA

No full text

Authority records BETA

Kjell, Andersson

Search in DiVA

By author/editor
Ahmad, AftabKjell, AnderssonSellgren, Ulf
By organisation
Machine Design (Div.)Machine Design (Dept.)
Other Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 90 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf